Anest Iwata iCon-M433N Manual Del Usuario página 10

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 83
Airless and Multi Spray iCon Pumps
10.2 USE
Before to supply air to the pump, con-
1
firm that the ball valve is open and
the air regulator is adjusted to 0 bar.
OPEN
OPEN
Fill the thinner cup up to 80% of
2
packings protection liquid.
Turn gradually the pressure regulator, adjust air pressure to a value slightly higher
5
than 2,0 bar, to enable the pump to release the air.
ICON-M333N / ICON-M433N
UP
7
Adjust the air pressure regulator, to the collect FLUID WORKING PRESSURE.
ICON-M333N / ICON-M433N
ADJ.
10
IMPORTANT
O BAR
Immerse the suction hose in the tank
3
with the paint to be pumped.
ICON-A333N / ICON-A433N
UP
ICON-A333N / ICON-A433N
ADJ.
BEFORE USE OF THE PUMP IT IS IMPORTANT TO READ
CAREFULLY AND OBSERVE THE WARNINGS AND CAUTIONS
CONTAINED IN THE INSTRUCTION MANUAL OF THE GUN TO
BE USE.
ICON-Mxx : MSGS-200 (Multi Spray Gun)
ICON-Axx: ALG-7 TE (Airless Spray Gun)
Open the drain valve for paint recir-
4
culation.
OPEN
Ensure that the paint comes out from
6
recirculation hose , then close the
drain valve.
CLOSE
Adjust the air pressure regulator, to
8
the collect ATOMIZING PRESSURE.
ICON-M333N / ICON-M433N
ADJ.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Icon-m333nIcon-a433nIcon-a333n

Tabla de contenido