ISEO Zero1 Atlas Plus Guia De Instalacion página 3

Ocultar thumbs Ver también para Zero1 Atlas Plus:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

V364 RFID SYSTEM WIRING:
3.
2 DOORS CONTROLLER CONNECTION EXAMPLE
BACK SIDE
J6
J11
J5
AT L A S
DOOR 1
(Stylos cod.5E1310126)
Back side view
circuit board
S1
DOOR 2
(Stylos cod.5E1310126)
Back side view
circuit board
S1
J7
J17
J4
J14
Power supply unit:
24 VDC - 1,65 A (35 W)
P1
L 1
ELECTRIC LOCK ACTUATOR
Cod. 5E2501**
LVO
JP 1
P1
L 1
DOOR 2
ELECTRIC LOCK ACTUATOR
Cod. 5E2501**
(Actuator
cod.5E2501)
LVO
JP 1
S3
S1
12 VAC
DOOR 1
L 2
P2
L R L
(Actuator
Power supply
cod.5E2501)
8÷ 30VDC 0.5A
LC H
JP 2
JP 3
L P W
12 VAC
L 2
P2
L R L
WIRING SPECIFICATIONS
Power supply
8÷ 30VDC 0.5A
LC H
JP 2
L P W
JP 3
NOT
shielded
Cable 3 x 0,75mm - AWG 18 NOT shielded
calculation of the cables section must be verified
by qualified staff).
Total LOCKBUS channel cable length (sum of all
branches): MAX 100mt.
Conductor capacitance < 100pF/m.
Conductors electrical resistance max 90 ohm/Km.
Wires colors reported in the wiring diagrams are just an example.
Suggested configuration for 2 doors
controller: max 4 Stylos readers.
Devices consumption:
- ATLAS = 10 W
- Stylos = 3W
- Actuator = 3W
Wirings also applies to Atlas Standard
DOOR 1
For the Stylos address configuration
refer to the Stylos Installation Guide,
available at: iseo.com.
DOOR 2
LOCKBUS
(+) V ALIM
( ) GND
2
(the

Publicidad