Installation of wall-hung Morsø 6670
The wall mounting is supplied with 8 holes for fixing to the
wall with expanding bolts. A minimum of 4 of the 8 holes in
the wall mounting must be used to fix the oven to the wall.
The bolts must be sized to ensure that the wall and the material
it is made of are capable of supporting the oven. The self weight
of the oven is 120 kg. The installer/ client must therefore ensure
that the wall/ chimney can support the oven in an appropriate
manner. Note that unit chimneys and unlined ½ brick chimneys
do not always have the necessary load-bearing capacity. If you
are in any doubt, you should therefore contact a qualified per-
son.
The wall mounting may be used as a drilling template. The
minimum clearance to a flammable floor is 360 mm.
Note that plastic wall plugs must not be used because
of the effects of heat.
A wall bushing must be built in correctly to the wall if a rear
smoke outlet is wanted (see sketch) and the wall mounting
must be fitted to the wall.
After unpacking the basic oven, remove the loose parts of
the oven. The ash drawer, the lower smoke baffle made of
vermiculite, the cast grate and the intermediate base should
be removed.