has accumulated on the walls or inside the tank. Then wipe the tank dry. Pour one tablespoonful of citric acid
into the tank and 100 ml of warm water with the temperature not exceeding 70
the solution in the tank for 5 minutes. Next, empty the tank, rinse with clean water, and wipe dry omitting the
opening in the bottom of the tank under which the ultrasonic generator is mounted. This manner of maintaining
the tank will allow to keep it clean, reduce the growth of microorganisms, and prevent the build-up of scale in
the tank. Never use solvents, acids, or alcohol for cleaning. Clean the base and the lid with a soft, damp cloth.
Never immerse the device in water or any other liquid. After cleaning, leave the lid and the base with the tank
to dry completely. Store the device in a place protected from dust, moisture, and direct sunlight. Before fi rst
use, wipe the inside of the tank with a damp cloth.

TECHNICAL DATA

Parameter
Catalogue No.
Rated voltage
Rated current
Container capacity
Steam emission capacity
Operation area
Weight
Power supply
Rated input voltage
Rated frequency
Rated current
Rated output voltage
Output current
Protection class
16
O R I G I N A L
GB
Unit
[VDC]
[mA]
[ml]
[ml/h]
[m
]
2
[kg]
[V~]
[Hz]
[A]
[VDC]
[mA]
I N S T R U C T I O N S
C. Mix the acid and leave
O
Value
66903
24
650
500
60
50
0,21
110 - 240
50 – 60
0,4
24
500
II