955191.book : I95519US.FM Seite 2 Montag, November 23, 1998 11:03 AM
13mm
E
Installation
See dimensional drawings fold-out page I.
Before mounting faucet:
Pre assemble components.
Side valves
The distance from the top of the handle connection
set to the bottom of the escutcheon must be 2",
see fig. [1].
[1]
Left close valve should be mounted on the right
(cold) side. Right close valve should be mounted
on the left (hot) side.
Valves are marked with a "L" (left close) or "R"
(right close) on the top edge of the cartridge.
Spout
- For installation you require only a 13mm socket
wrench or screwdriver, see fig. [2].
- Fit swivel spout, see fig. [2].
- Connect flexible hoses (A) from spout body to side
[2]
valves, see fig. [3].
Connect spray hose with handspray
(Do not use additional seals)
- Insert spray hose (B) complete with handspray (C)
from above through the spray holder (D), see
fig. [4].
- Connect spray hose (B) to swivel connection (E) of
the spout body.
A
[3]
Flush pipes thoroughly.
C
Connect wideset
For this purpose the supply tubes must be con-
D
nected to the angle stops (or other supply points).
The hot water supply should be connected on the
B
left, the cold water supply on the right side.
Open angle stops and check function of faucet.
[4]
Check connections for leakage.
English
2