DS191 SW MV WIFI: CONTROL BOARD FOR SWING GATES
O
NOTE: WHEN CONNECTING AERIAL ANTENNA, MAKE IT ALWAYS WITHOUT CURRENT.
ATTENTION:
Safety devices:
• Option 1 (connect 11 and 14): door stops and closes.
• Option 2 (connect 12 and 14): door stops and opens.
• Option 3 (connect 13 and 14): door stops.
AMPERE-STOP (RED)
POWER (BLUE)
Engine power regulation. Rotate to the LEFT to decrease it and rotate to the RIGHT to
increase it.
SOT STOP (WHITE)
Soft stop motor regulation. Only with Option 7 ON. Rotate to the LEFT to decrease it and
rotate to the RIGHT to inc rease it. Available for opening and closing.
CONNECTIONS
REGULATIONS
DISABLED
OPTION LAMP
15
OPTION FLASH
ANTENA
24 25