Flashing Light - Daspi DS191 SW MV Funcionamiento

Cuadro de control para puertas batientes
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

WOLF SW MV: CONTROL BOARD FOR SWING GATES
AUTOMATIC CLOSING TIME (GREEN)
Regulates the stand-by time before the automatic closure. Turn to the LEFT to decrease it and to the
RIGHT to increase it.
Minimum 3 seconds.
Maximum 120 seconds.
1 AUTOMATIC CLOSURE
ON: Activated. Door closes automatically.
OFF: Deactivated. Door does not close automatically.
2 COMUNITY/CLOSE BY PHOTOCELL
ON Inhibitor of the transmitter or START during opening. During closing, activating the START or
the transmitter reverses the maneuver. THE DOOR CLOSES THE AUTOMATIC CLOSING TIME HAS
PASSED OR ONCE 5 SECONDS AFTER CUTTING THE PHOTOCELL.
Dip 1 must be activated for this option to work.
OFF START switch (1-2) and transmitter, door work normal, step by step.
3
ON: Start the closing maneuver once the photocell is cut and spend 5 seconds.
Automatic closure deactivated.
OFF
4 INVERSION SHUT
Before opening, the electro lock and closure relay are activated. At the end of the
ON:
closing maneuver tightening time 2 sec for safety.
Normal opening with electro lock.
OFF:
5 OPEN SECURITY CONTACT (CSEG1)
CSEG input stops and inverts 2 seconds the opening maneuver. On closing, stops
ON:
and inverts the maneuver.
CSEG1 input stops the opening maneuver. When CSEG1 is deactivated, the door
OFF:
opens again.

6 FLASHING LIGHT

Flashing.
ON:
Fixed.
OFF:
OPTIONS