Tool Specifications; Operating Controls; Intended Use; Before Use - Wurth Master WAC 70 Traducción Del Manual Original

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 22
0701 407 2.book Seite 11 Dienstag, 9. Februar 2010 1:47 13
Wet Tile Saw
Article number
Input power
No-load speed
Blade diameter
Hole
Max. sawing height
Max. sawing length
Saw table dim. (LxB)
Dimensions (LxBxH)
Weight
Safety class

Operating Controls

1 Motor
2 On/Off switch
3 Motor flange
4 Saw flange
5 Flange nut
6 Capacitor
7 Pump
8 Knob/legs
9 Clamping lever
10 Guiding roll
11 Guiding rail
12 Grip
13 PRCD protective switch*
14 Transportation lock
15 Knob/cutting depth
*Not all of the accessories illustrated or described
areincluded as standard delivery.

Intended Use

The sawing machine is only to be used for sawing
tiles, marble and ceramics in combination with wet-
diamond blades and a sufficient supply of water.
For damage caused by usage other then intended,
the user is responsible.

Tool Specifications

WAC 70
WAC 90
0701 407 2
0701 409 2
1000 W
1500 W
2800
-1
min
2800
Ø 200 mm
Ø 250 mm
Ø 25.4 mm
Ø 25.4 mm
35 mm
50 mm
700 mm
900 mm
575 x 360 mm
890 x 435 mm
1050 x 400 x 400 mm 1230 x 450 x 650 mm 1540 x 450 x 600 mm
41 kg
52 kg
/I
/I
Always use the correct supply voltage: The power
supply voltage must match the information quoted
on the tool identification plate.
On construction sites electrical appliances
should be connected to specially designed
power supplies.
Suitable are grounded main power supplies
equipped with an earthleak switch of max.
30 mA or separating transformers.
Non-grounded common household or simi-
lar power outlets are not suited as a power
source.
For water cooled sawing machines stricter safety
standards are applicable. Therefore, for extra safety
the machine must be connected according to one of
the following methods:
Main power supply equipped with earthleak switch*
30 mA.
--------------------- or ---------------------
Separating transformer*, only 1 machine may be
connected at any given time.
--------------------- or ---------------------
With an intermediate cable equipped with a PRCD
safety switch* of max. 30 mA.
* Not included as standard delivery.
WAC 120
0701 401 2
1500 W
-1
2800
-1
min
min
Ø 250 mm
Ø 25.4 mm
50 mm
1200 mm
1200 x 435 mm
62 kg
/I

Before Use

11

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Wac 90Wac 1200701 407 20701 409 20701 401 2