SISTEMA SOLAR CON DEPÓSITO INTEGRADO OKSOL Y OKSOL-SMART
OKSOL AND OKSOL-SMART SOLAR SYSTEM WITH INTEGRATED WATER TANK
SYSTÈME SOLAIRE AVEC RÉSERVOIR INTÉGRÉ OKSOL ET OKSOL-SMART
MANUAL DE INSTALACIÓN KIT RESISTENCIA ELÉCTRICA
INSTALLATION MANUAL ELECTRICAL RESISTANCE KIT
MANUEL D'INSTALLATION KIT DE RÉSISTANCE ÉLECTRIQUE

Publicidad

loading

Resumen de contenidos para Orkli OKSOL

  • Página 1 SISTEMA SOLAR CON DEPÓSITO INTEGRADO OKSOL Y OKSOL-SMART OKSOL AND OKSOL-SMART SOLAR SYSTEM WITH INTEGRATED WATER TANK SYSTÈME SOLAIRE AVEC RÉSERVOIR INTÉGRÉ OKSOL ET OKSOL-SMART MANUAL DE INSTALACIÓN KIT RESISTENCIA ELÉCTRICA INSTALLATION MANUAL ELECTRICAL RESISTANCE KIT MANUEL D’INSTALLATION KIT DE RÉSISTANCE ÉLECTRIQUE...
  • Página 2 0. ADVERTENCIAS • El montaje del kit de resistencia eléctrica para los sistemas OKSOL y OKSOL SMART debe ser realizado por personal cualificado. • Para evitar daños al sistema OKSOL y OKSOL SMART sólo se debe utilizar la resistencia eléctrica suministrada por el fabricante.
  • Página 3 RACORD PRENSAESTOPAS RESISTENCIA TUERCA PRENSAESTOPAS 1.2 Kit resistencia eléctrica SMART V-10857 RESISTENCIA + TERMOSTATO + JUNTA CIERRE + CAPUCHÓN ELECTRÓNICA DE CONTROL DE LA RESISTENCIA CONEXIÓN ENTRE ELECTRÓNICA IoT OKSOL Y ELECTRÓNICA RESISTENCIA RACORD CONEXIÓN PRENSAESTOPAS RESISTENCIA TUERCA PRENSAESTOPAS CONEXIÓN ENTRADA TENSIÓN...
  • Página 4 2. PROCESO INSTALACIÓN KIT RESISTENCIA ELÉCTRICA • Retirar la tapa lateral (y los aislantes aluminizados) del OKSOL. • Desenroscar el tapón de plástico de rosca G-1 ¼”, e introducir en su lugar la resistencia eléctrica. • Apretar de manera que no haya fugas y no se deforme en exceso la junta de cierre suministrada.
  • Página 5 • Conectar el terminal de tierra en el conector “Faston” existente en la tapa metálica, y volver a proteger el termostato con su capuchón. CONECTOR “FASTON” (TIERRA) • SOLO PARA KIT RESISTENCIA ELECTRICA SMART: interconectar la electrónica IOT del OKSOL con la electrónica de resistencia. CONECTOR PARA ELECTRÓNICA DE CONTROL DE LA RESISTENCIA ELECTRÓNICA IoT...
  • Página 6 TUERCA RÁCORD Pasos para la instalación del rácord prensaestopas: 1. Cortar parte del 2. Taladrar agujero Ø20. aislante para agujerear la tapa. 4. Pasar cable para que 3. Colocar prensaestopa la conexión quede en con tuerca. el interior del OKSOL.
  • Página 7 3. PRODUCCIÓN DEL OKSOL TRAS LA INCORPORACIÓN DEL KIT DE RESISTENCIA ELÉCTRICA La máxima carga diaria de agua caliente que puede ser suministrada por el sistema sin ninguna contribución de energía solar se produce para volúmenes de cargas diarias menores a 50 l/día.
  • Página 8: Filling Valve

    Only operate the system under cover or with low solar irradiation (high cloud cover). • The storage tank of the OKSOL system must be empty or at least below the level of the electrical resistance connection.
  • Página 9 THERMOSTAT CONTROL + SAFETY SEALING GASKET CABLE GLAND RESISTANCE PACKING NUT 1.2 Electrical resistance kit SMART V-10857 RESISTANCE+THERMOSTAT+SEALING GASKET+PLASTIC CAP CONTROL ELECTRONICS OF THE RESISTANCE CONNECTION BETWEEN OKSOL IOT ELECTRONICS AND RESISTANCE ELECTRONICS CABLE GLAND RESISTANCE CONNECTION PACKING NUT VOLTAGE INPUT CONNECTION...
  • Página 10 2. ELECTRICAL RESISTANCE KIT INSTALLATION PROCESS • Remove the side cover (and the aluminized insulators) from the OKSOL. • Unscrew the G-1 ¼” plastic plug, and insert the electrical resistance in its place. • Tighten in such a way that there is no leakage and the sealing gasket supplied is not excessively deformed.
  • Página 11 • Connect the ground terminal to the existing “Faston” connector on the metal cover, and protect the thermostat again with its cap. FASTON CONNECT (GROUND) • ONLY FOR SMART ELECTRIC RESISTANCE KIT: interconnect the OKSOL IOT electronics with the resistance electronics. CONNECTOR FOR RESISTANCE CONTROL ELECTRONICS...
  • Página 12 Steps for the installation of the cable gland: 1. Cut off part of the 2. Drill hole Ø20. insulation to make a hole in the side cover. 4. Pass the cable 3. Fit cable gland with through so that the nut. connection is inside the OKSOL.
  • Página 13 3. PRODUCTION OF OKSOL AFTER INCORPORATION OF THE ELECTRICAL RESISTANCE KIT The maximum daily hot water load that can be supplied by the system without any solar energy contribution occurs for daily load volumes of less than 50 l/day. Thermal performance of the system for the recommended load range, for the locations and reference...
  • Página 14: Avertissements

    N’intervenez que lorsque la température du collecteur est sûre. Fonctionne uniquement lorsque le système est couvert ou lorsque le rayonnement solaire est faible (couverture nuageuse élevée). • Le réservoir de stockage du système OKSOL doit être vide, ou au moins en dessous du niveau de la connexion de la résistance électrique.
  • Página 15 GAINE DE CÂBLE RÉSISTANCE ÉCROU 1.2 Kit de résistance électrique SMART V-10857 RÉSISTANCE + THERMOSTAT + JOINT D’ÉTANCHÉITÉ + BOUCHON ÉLECTRONIQUE DE CONTRÔLE DE RÉSISTANCE CONNEXION ENTRE L’ÉLECTRONIQUE OKSOL IoT ET L’ÉLECTRONIQUE DE RÉSISTANCE RÉSISTANCE GAINE DE CÂBLE DE LA CONNEXION ÉCROU...
  • Página 16 2. PROCÉDURE D’INSTALLATION DU KIT DE RÉSISTANCE ÉLECTRIQUE • Retirez le couvercle latéral (et les isolateurs aluminisés) de l’OKSOL. • Dévissez le bouchon à vis en plastique G-1 ¼», et insérez la résistance électrique à sa place. • Serrez de manière à ce qu’il n’y ait aucune fuite et aucune déformation excessive du joint d’étanchéité...
  • Página 17 • Connectez la borne de terre au connecteur «Faston» existant sur le couvercle métallique, et protégez à nouveau le thermostat avec le capuchon du thermostat. CONNECTEUR FASTON (TERRE) • UNIQUEMENT POUR LE KIT DE RÉSISTANCE ÉLECTRIQUE SMART : interconnecter l’électronique IOT OKSOL avec l’électronique de résistance. CONNECTEUR POUR L’ÉLECTRONIQUE DE CONTRÔLE DES RÉSISTANCES ÉLECTRONIQUE...
  • Página 18 1. Coupez une partie 2. Trou de perçage Ø20. de l’isolation pour faire un trou dans le couvercle. 4. Acheminez le câble 3. Monter le presse- de manière à ce étoupe avec l’écrou. que la connexion soit à l’intérieur de l’OKSOL.
  • Página 19 3. PRODUCTION DE L ’OKSOL APRÈS INCORPORATION DU KIT DE RÉSISTANCE ÉLECTRIQUE La charge maximale quotidienne d’eau chaude qui peut être fournie par le système sans aucune contribution de l’énergie solaire se produit pour des volumes de charge quotidiens inférieurs à 50 l/jour.
  • Página 20 ORKLI, S. Coop. Ctra. Zaldibia, s/n E - 20240 Ordizia (Gipuzkoa) Tel.: + 34 943 80 51 80 Fax: + 34 943 80 52 41 E-mail: cal@orkli.es www.orkli.com...