Electrical Connection - Leuze electronic CU405-2M12 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
EN

Electrical connection

The data regarding the electrical supply of the RSL 410 applies to the voltage supply
and the switching outputs (see the
chapter 8 "Electrical connection" and chapter 15 "Technical data").
NOTE
 Make sure that the voltage supply is suitable for the RSL 410.
NOTE
Laying cables!
 Lay all connection cables and signal lines within the electrical installation
space or permanently in cable ducts.
 Lay the cables and lines so that they are protected against external damages.
 For further information: see EN ISO 13849-2, Table D.4.
Pin assignment
2
ETH, M12 socket, D-coded
Pin No.
Signal
1
TD+
2
TD-
3
RD+
4
RD-
FE
GND/shield
Connect the M12 housing/cable shield to the functional earth via the
RSL housing
X1, X2, M12 plug, A-coded
Pin No.
X1
Signal
1
+24 V DC
2
OSSDA2
Safe switching output
3
0 V
4
OSSDA1
Safe switching output
FE
Connect the M12 housing/cable shield to the functional earth via the
RSL housing
12
original operating instructions
X2
Signal
Not used
Not used
Not used
MELD
Signal output
for the RSL 410,

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Rsl 410

Tabla de contenido