Electronic Ballast dimmable 600W
EN
Legend
1. OFF-Standby button
2. Up / down button
3. LED overdriver
4. LED 600W mode
5. LED 400W mode
6. LED 250W mode
7. LED OFF-Standby ---ERROR---
8. Lamp cable
9. Power cable
Wiring
Connect the lamp cable to reflector or E40 lamp holder.
(Only for authorised persons)
Choose a bulb
Connect a desired bulb 250W, 400W or 600W MH (metal highlight) or
HPS (high pressure sodium) into the E40 lamp holder or reflector.
Connect the main cable to a house hold socket 230V/50Hz.
Now the ballast is initialising all LED are blinking for for about 5 seconds.
After this the 7. LED OFF-Standby ---ERROR--- is on, 4. LED 600W
mode is blinking. Choose now with the 2. Up / down button the wattage
of the bulb, confirm with 1. OFF-Standby button, the
7. LED OFF-Standby ---ERROR--- will constantly shine.
Warning: in case you choose higher wattage as the bulb is you will
seriously damage the bulb.
Start the ballast
Once you have choose the correct wattage start the bulb pushing the
1. OFF-Standby button. This can least up to 15-20 seconds to start the
bulb the first time. The ballast stores the ignition information. Next time
the bulb start immediately. In case the ballast can not start bulb in the first 15-20
seconds the ballast will try again after a 2minutes cool down time. During this
time the 7. LED OFF-Standby ---ERROR--- is blinking 2 times. During this time
the 7. LED OFF-Standby ---ERROR--- is blinking 2times. During this operation
you can not dim or change the Watt.
10
Activate you warranty online http://g-systems.eu/warranty/
In case of ignition failure the ballast will try this operation 5x and after this stop
working. You have to start the ballast manually again. Once the bulb started it
needs 3-5minutes to get hot and shine on his full power. In case the ballast can
not start the bulb contact our support team using the live support on
http://www.g-systems.eu/
Stop the ballast
You can stop the ballast manually with the
1. OFF-Standby button, or disconnecting the power on the main cable. The
ballast stors your settings for about 72h and starts next time with the last
settings. After 72h disconected or OFF the ballast loses the settings and you
have to start it manually again.
Dim the bulb
You can dim a bulb only downwards, for example:
600W dim to 250W ;
400W dim to 250W ;
250W is not dimmable
A 600W bulb can run on overdrive which is 10% more output power to
the bulb. (We do not recommend it cause it damages the bulb).
GSE don't recommend to dim any kind of bulbs because the light colour
changes). For dimming push short to 2. Up / down button it steps at
once from 3. LED overdriver to 4. LED 600W mode to 5. LED 400W
mode and 6. LED 250W mode. The ballast needs up to 2minute time to
dim the bulb can cool down his self. When you push the 2. Up / down
button and hold it the ballast dim variable. The LED are indicating the
the value. Between 600W and 500W the 4. LED 600W mode shine and
the 5. LED 400W mode is blinking, between 500W and 400W the 5.
LED 400W mode shine and the 4. LED 600W mode is blinking. The
same functions you have between 400W and 250W. The ballast
remembers thesettings at the next start, the ballast lose the settings
after 72h disconnected or switch OFF you have to start manually again.
Safety instruction
The electronic ballast must be connected into a common household plug
which has a 10A, 13A or 16A safety breaker. To avoid injury, disconnect the power
cable before opening. The ballast have 2fuse inside, in case of total
failure check first the fuse. In case the fuse are o.k. and the ballast is
not working use our RMA http://g-systems.eu/warranty/rma to return
the ballast for repair.
EN