Transport And Storage - almson NXL Instalacion Y Puesta En Servicio

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ENGLISH
1 GENERAL
1.1. Applications
For faster circulation of water in open- and closed-
circuit domestic (individual) central heating and air-
conditioning systems.
1.2. Specifications
• Temperature range
• Ambient temperature
• Max. service pressure
• Min. suction pressure
(m w.g.*)
• Antifreeze (Water + glycol) : up to 50 %
(whith the exclusion of all other liquids without first
obtaining the agreement).
•Max. flowrate (50 Hz) NXL - NYL 13
NXL - NYL 33
CXL 2020 and NXL - NYL 43
NXL - NYL 53
NXL - NYL 63
* 10.2 m w.g. = 1 bar
2. SAFETY
Read this data sheet carefully before installing and
starting up. Pay special attention to the points
concerning the safety of the equipment for the
intermediate or end user.
2.1. Symbols used in the manual
Warning.
Instructions concerning electricity.
Calls attention to a potential risk that
ATTENTION !
might affect safety.

3. TRANSPORT AND STORAGE

When taking delivery of the equipment, check that it
has not been damaged in transit. If anything is found
wrong, take the necessary steps with the carrier within
the allowed time.
If the equipment delivered is to be installed at a
later time, store it in a dry place and protect it
from impacts and outside influences (moisture, frost,
etc.).
: -10° to +110°C
: up to 40°C
: 10 bar
: 1.5 m (0.15 bar)
at + 82°C;
: 3 m (0.3 bar)
at +95°C;
: 10 m (1 bar) at +100°C
: 2,5 m
3
/h
: 3 m
3
/h
3
: 3,5 m
/h
: 4 m
3
/h
: 4,5 m
3
/h
4. PRODUCTS AND ACCESSORIES
4.1. The pump
With threaded ports or ovales flange according to
model.
The motor has a wet rotor and the bushings are self-
lubricating.
Three-speed or multi-speed, according to model;
manual selection by selector switch.
• Compliance
• Insulation class
• Protection
The motor is self-protected and needs no external
protection.
Frequency
Voltage * (1-phase)
* standard voltage : tolerance 50 Hz ± 10 % - 60 Hz ± 6 %
4.2. Accessories
supplied : Union's gasket or flange's gasket
Recommended :
• Unions or screw-on oval counter-flanges.
• Unjamming plug device for motor shaft.
• Isolating valves.
5. INSTALLATION
5.1. Assembly (see FIG. 1)
Make sure that the circulator is accessible.
-
- Assemble directly on a pipe, preferably vertical, and
if possible on the boiler return circuit; never at the low
point (to protect against deposits).
- The motor shaft axis must always be horizontal.
- The arrow on the pump casing indicates the
direction of water flow (see FIG. 2).
- Install isolating valves on both sides of the circulator
to facilitate removal and other work on it.
If the circulator must be insulated, we
ATTENTION !
advise
evacuation notches in the motor flange (see FIG. 2).
5.2. Orientation of terminal box (see FIG. 3)
If necessary, the orientation of the motor, and with it
that of the terminal box, can be changed.
(12 h and 6 h only for NZL)
Remove the motor attachment screws and turn the
-
motor to the desired position.
Take care not to damage the casing gasket,
and reinstall it correctly.
The terminal box should not be placed at 3 and
6 o'clock on an ice water circuit.
6
: TF110
: F (155°C)
: IP42
50 Hz
60 Hz
230 V
220/240 V
against
obstructing
the

Publicidad

Tabla de contenido
loading

Productos relacionados para almson NXL

Este manual también es adecuado para:

NylNzlCxl2020DylHxl

Tabla de contenido