Line Lock Phase Adjustment
Potentiometer
When the camera is in Line lock mode, it is possible to
adjust the point on the AC cycle at which the camera
triggers. This feature allows for synchronization of cameras
that are connected to different phases.
The V-PHASE adjustment potentiometer allows the line
lock phase trigger point to be adjusted by 270°. Rotating
the potentiometer clockwise advances the trigger point and
turning it counterclockwise retards the trigger point. If all
cameras in a system are on the same phase then no line
lock phase adjustment should be made.