MAGNOLIA
To cover the front and sides of the bathtub, you can either use the plastic Magnolia Covering Panels, or follow the
classical mason technology to encase and face it choose the solution that suits your bathroom the best. To set the
bathtub into a niche, the walls must include the exact 90° angle!
INSTALLING YOUR BATHTUB
1.
The bathtub can be installed in a finished and fully tiled bathroom only. In case the tiling on the bathroom walls
does not reach the floor, make sure it reaches at least 150 mm under the upper edge of the bathtub.
2.
If you intend to encase the bathtub, the lining must follow its features and reach maximally 20 mm under its outer
edge, and its height 2-3 mm under the trim. See the detail on
remember to leave out some openings in the masonry to reach the outflow siphon and water delivery. You can
cover these openings e.g. with a tile fixed by magnets, or with a door.
3.
Water delivery: Ø ¾" or ½". For a wall-hung mixing tap build an opening about 800 mm above the floor, in the most convenient location.
4.
Outfall for the siphon: Ø 50 mm. Build it close to the bathtub outfall, avoiding the future location of the supportive legs.
B/ INSTALLATION AND ENCASING INSTRUCTIONS
(without covering panels)
5.
During the installation, keep the protective foil on the bathtub and work with caution.
6.
Set the bathtub upside down and put the cardboard and polystyrene package pieces on its corners to protect the
bathtub edges from damages.
7.
Following the
pic.3
dimension the positions for metal girders bearing the supportive legs. Adjust the girders
(using the asymmetrically placed openings in the girders or turning the girders) so that they are not in the way of
the casing. Mark out the openings for mounting bolts on the thickened bottom of the bathtub.
8.
Use a Ø 3 mm drill to make 10 mm deep openings on the marked out positions.
9.
Complete the supportive legs with the girder and screw it onto the bathtub.
some sealing putty under the girder ends.
10.
By twisting the legs, set the complete height of the bathtub (including the legs) on 610 mm.
11.
Set the bathtub into its final location, and control (and adjust by twisting the legs if necessary) the gap between
the bathtub and casing.
12.
Make sure all the edges are level, only then tighten the securing nuts on the supportive legs.
13.
Mark on the floor the position of the outflow siphon.
14.
Mark on the walls the line of the upper bathtub edge it must be 610 mm (5 mm tolerance allowed) above the
floor level.
See pic.2.
15.
Carefully pit the bathtub aside.
16.
Fix the mounting clamps 55 mm under the line of the upper bathtub edge -that is 555 mm above the floor level.
Openings for the plugs: Ø 8 mm.
17.
Mount the clamps using Ø 4x40 mm bolts.
18.
We recommend you to equip your bathtub with a Ravak outflow complex
Ø outflow pipes to be connected to the siphon.
19.
Following the instruction leaflet included in the package, install the outflow complex.
20.
Prior to final setting of the bathtub, stick a self-adhesive foam strip on those of its edges that will fit to the wall, about 10 mm under the upper edge. Apply
sealing putty into the mounting clamps and insert the vertical bathtub edge into them.
21.
Finish the installation and connecting of the outflow siphon.
22.
Seal the gaps between the bathtub, wall tiling and casing.
!
C/ INSTALLATION OF PLASTIC COVERING PANELS AND PANELKIT
If you choose to install your bathtub with the PLASTIC COVERING PANELS, follow the instructions included with the
panel already when mounting the supports.
If you want your bathtub to serve you dependably for a long time, please obey the following recommendations:
- Clean your bathtub with common detergents and a soft cloth after every use.
desinfectants, that contain chlorine.
- Fill the bathtub first with cold water before you add hot.
- Have the dripping tap repaired immediately.
- Solvents and thinners, as well as nail polish and nail polish remover damage the bathtub surface.
- Hot things such as curling irons or lit cigarette can also damage the acrylic.
- Water sediments can be removed by water with a little vinegar dissolved in it. Minor scratches can be smoothed out with polishing agents.
The manufacturer recommends a RAVAK ANTICALC products range for maintenance:
RAVAK CLEANER to remove old stubborn dirt off glass surfaces, shower enclosure frames, enamel and acrylic bathtubs, washbasins and water taps.
RAVAK DESINFECTANT a special detergent with high anti-bacterial and fungicide effects.
The manufacturer extends a 10 years guarantee on the condition that the product has been professionally installed and used only for personal
hygiene and relaxation of grown-ups and children.
The guarantee cannot be claimed in any other way of using the bathtub, or when installed without the supportive legs, or when rigidly imbedded.
The manufacturer reserves the right to change the price, technical parameters or other facts without a prior notice and shall bear no responsibility for the printing errors.
See pic.1.
See pic.1 -section A-A.
MAINTENANCE, CLEANING, GUARANTEE
A/ BUILDING PREPARATION
pic.1-section B-B.
When encasing the bathtub,
Pic.4.
We recommend you to apply
(see pic.5),
which can be ordered together with the bathtub. Prepare 40 mm
See pic.1-section A-A.
Never use any abrasive pastes, dissolvents, acetone or detergents and
RAVAK a.s.,
Obecnická 285, 261 01 Pøíbram I
Èeská republika
tel.: +420 318 427 200, 427 111
fax: +420 318-427 269, 427 278
e-mail: smith@ravak.cz
www.ravak.com
MOUNTING KIT SUPPORT
1. Metal girder 650 mm length
2. Plastic leg M12
3. Clamp
4. Plug Ø 8 mm
5. Bolt for the plug Ø 4x40 mm
6. Bolt Ø 5.5x16 mm
See pic. 2.
7. Drill bit Ø 3 mm
8. Washer
9. Thread Rod M12x85
10. Nut M12
11. Self-adhesive Foam Strip
See pic.2
An acrylic bathtub must never be
rigidly imbedded. Carrier part of
the bathtub is the reinforced
bottom equipped with the
supportive legs. A gap of 2-3 mm
must remain between the case
tiling and the bathtub edge until
the installation is completed, then
the gap is sealed.
Use a stop when drilling the
bathtub bottom, to prevent any
damages to the plastic.
2 pcs
6 pcs
4 pcs
4 pcs
4 pcs
8 pcs
1 pc
4 pcs
6 pcs
18 pcs
2,5 m
ATTENTION!
ATTENTION!
!