Quick Start Guide CellaCast PX 8x
EN
1
Ratio correction
2
Temperature difference [°C]
Experience has shown that the following settings apply as a first approximation
- grey pig iron 101
- spheroidal graphite iron 104
However, these values may differ in practice. After changing the emissivity ratio, carry out a new
control measurement.
The emissivity ratio is set as follows:
► Press [▲ or ▼] for 2 seconds
> The value of the selected emissivity ration is displayed, for example [103 . 0 ]
► Press [▲ or ▼] until the desired emissivity ratio will show
► Release the [▲ or ▼] key
> The current temperature values is displayed and the new emissivity ration coefficient is
stored
Alternatively, the emissivity ratio can be set via IO-Link.
11 IO-Link
This device has an IO-Link communication interface, which requires an IO-Linkcapable module
(IO-Link master) for operation.The IO-Link interface allows direct access to process and diag-
nostic data and offers the possibility to parameterize the device during operation.