KIT
VIDEOPORTERO DIGITAL 5 HILOS
VIDEOPORTERO DIGITAL 5 HILOS
KIT WIRING DIAGRAM
Vac
POWER
SUPPLY
JP2
Ct L
+ -
12 Vdc
NOTE: The power supply may be placed at an intermediate point in the installation.
Maximum distance from panel: 30 metres.
Pag 42
+
-
+
-
EXT.
ADS KIT
PLAC
AMPLIFIER
INT.
TELEFONO
C
Nc
-
+
S
B
B
No
+12
CAMERA
CT
V+ V-
..........
.......... ....
....
A 10 Kohm resistance must be placed
between the monitor terminals + and L. A
bag with 5 resistances is included with
the kit.
For distances over 100 metres or
additional equipment sets.
V-
DISTANCE
V+
+
L
-
100 a 200
CAT 5 UTP 4 pair cable, up to a
maximum distance of 100
metres.
CN2
Vo+
Vo-
Vi+
10 Kohm
Vi-
+
L
-
CT
+A
-A
J1 PRG
CROSS
SECTION
(meters)
1 a 50
1
mm
50 a 100
1,5
mm
2,5
mm
HIGH RESOLUTION
FLAT MONITOR
1
2
2
2
2
V+
V-
+
-
L