PROBLEM
Heating element not hot
Thermal fuse burned out Thermal fuse defective
I'm not getting a suffi-
ciently dense product
I'm not getting a suffi-
ciently hot product
CAUSE
Heating element burned out
Thermal fuse burned out
The temperature of the
service thermostat (located on
the side of the distributor) is
set too low
Product excessively diluted
The temperature of the
service thermostat (located on
the side of the distributor) is
set too low
The bottom of the tub is not
touching the heating element
9
SOLUTION
R e p l a c e t h e h e a t i n g
element
Adjust it to a suitable
temperature
Replace with a good one
A d j u s t i t t o a s u i t a b l e
temperature
Increase the concentration
of the product
A d j u s t i t t o a s u i t a b l e
temperature
Position the tub on the
heating element correctly