GB
Specification
TF Series Manual
Construction
Wetside material
Gasket
(1" BSPP (G1) only)
Housing Code
A
Housing
PA66 30%GF
material
LED Window
PMMA
Conduit Entry
M20
IP66/67 to
Weather
EN60529,
proofing
NEMA 4X
Operating conditions
Wetside temp.
Ambient temp.
Wetside pressure
Liquid sg
Liquid viscosity
Switching point (H
0)
2
Hysteresis (water)
Switching delay
Maximum altitude
Electrical
Switching mode
Protection
Terminal connection
(wire diameter)
Cable gland
Earthing
Safety EMC
E.M.C. Directive
L.V. Directive
www.hycontrol.com
316L Stainless steel (1.4044),
Hastalloy C (C276),
PFA/ECTFE co-polymer coating
Non-asbestos BS7531 Grade X carbon
fibre with rubber binder
D
X
Al alloy ASTM
B26 356-T6
½"
M20
¾" NPT
NPT
IP66/67 to
EN60529, NEMA
4X, 7
-40°C to +150°C
-40°C to + 80°C
(derated to 50°C at 150°C wetside)
-0.25 bar g to +100 bar g at 50°C
(30 bar for hygienic fittings)
0.6 to 2.0
0.2 to 10,000 cps
13 mm from tip (vertical)
13 mm from edge (horizontal)
±1 mm nom.
0.3, 1, 3, 10, 30 sec dry to wet / wet to dry.
2000 metres
User selectable (Dry = on or Wet = on)
Reverse polarity protected. Missing load / short
circuit protection.
2
Max. 2.5 mm
(Note national regulations)
Supplied with PA66 only – cable dia. 5 mm to 8 mm.
The tuning fork should always be earthed either through
terminals or using external earth connection provided.
BS EN61326:1998 (Emmissions)
for Class B Equipment
BS EN61326:1998 (Immunity)
for continuous unmonitored operation in industrial locations
EN61010-1
Pollution degree 2, Category II (264V max)
Pollution degree 2, Category III (150V max)
Y
Page 29