SPECIFICATIONS
Air tank capacity
Air flow
Air pressure
Tank pressure gauge
Regulatory pressure
gauge
Net weight
Working environment
Humidity
Altitude
Storage environment
Rated current
Short current rate
Motor speed
KNOW YOUR AIR Compressor
See figure 1.
The safe use of this product requires an understanding
of the information on the product and in this operating
manual as well as a knowledge of the project you are
attempting. Before using this product, familiarize yourself
with all operating features and safety requirements.
Carrying handle
The air compressor has a carrying handle for easy
transport.
Drain valve
The drain valve on the tank is for draining condensation to
help prevent tank corrosion.
Oil-free pump
The oil-free pump reduces the need for maintenance.
Pressure regulator knob
Use the pressure regulator knob to adjust the amount of
air being delivered through the hose.
Quick coupler
The air compressor has a quick connect coupler
located on the side of the unit.
Regulatory pressure gauge
The current line pressure is displayed on the regulatory
pressure gauge. This pressure can be adjusted by rotating
the pressure regulator knob.
2 L
40L/min
8 bar max
40 mm diameter
40 mm diameter
5.2 kg
+5~40 °C
< 50 %
≤ 1000 m
-25~+55 °C
6 A
8 kA
4600/min
English
Safety valve
The safety valve is designed to automatically release air if
the air tank pressure exceeds the preset maximum.
Tank pressure gauge
The tank pressure gauge indicates the pressure of the air
in the tank.
Vertical storage
The air compressor has been designed to safely stow in
the horizontal or upright position. The greatest permissible
inclination from the horizontal is 10°.
OPERATION
ATTACHING AIR HOSE TO COMPRESSOR
1, Using your left hand push quick connect towards the
body of the compressor.
2, Firmly press fit the male quick connect portion on the
air hose into the female quick connect and release female
quick connect locking hose in place.
Fig. 2
RECOIL HOSE
NOTE: When connecting or disconnecting air hose
remove air from tank.
OPERATION
BATTERY(sold separately)
IMPORTANT! The battery pack is not charged when it is
purchased. Before using the air compressor for the first
time, place the battery pack in the battery charger and
charge. Make sure to read all safety precautions, and
follow the instructions in the Battery Charger section.(sold
separately)
To install (See Figure 2.)
1. Align the tongue (3) of the battery pack with the cavity
(4) in the air compressor housing.(sold separately)
2. Grasp the air compressor (2) firmly.
3. Push the battery pack into the handle until the latch
locks into place.(sold separately)