Dometic MCS5 Instrucciones De Montaje página 16

Ocultar thumbs Ver también para MCS5:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 102
_IA_MCS.book Seite 16 Mittwoch, 28. Januar 2009 9:06 09
Installation
8.1
Spacing Allowances and Unit Dimensions
Key to fig. 2, page 3:
Item
Note
I
The blower and duct ring can be positioned either vertically or
horizontally; fig. 2, page 3 shows a Marine Climate System MCS5 with
blower rotated to vertical position.
Space allowances (fig. 2, page 3)
The following space allowances should be considered when mounting
the unit:
Allow a minimum of 152 mm around the perimeter of the unit in the
area of the seawater and condensate drain piping (1).
Allow a minimum of 76 mm of air space in front of the evaporator coil
for the return-air intake if it is adjacent to a bulkhead (2).
For flexible ducting connection (10) and for clearance needed behind
the supply-air grille
– allow 51 mm for the duct ring,
– allow 25 mm for the duct bend radius and
– add diameter of the ducting to get the total clearance distance.
Allocate enough space for installation and serviceability.
16
Description
1
Space allowance for return-air intake
(if adjacent to bulkhead)
2
Space allowance for seawater piping
3
Evaporator and condenser coil
4
Duct ring
5
Electric box
6
Rotary compressor
7
Refrigent connection
(allow space for access)
8
Seawater in
9
Seawater out
10
Total minimum clearance
11
Standard blower position as shipped
12
Possible drain position
MCS5, MCS15

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Mcs15

Tabla de contenido