1
GAS PRESSURE CONVERSION KIT
1.1
Conversion from 30 mbar to 50
mbar (BUTANE/PROPANE)
B Remove the screws and remove the main burner (Fig.
1).
Fig. 1
B Replace the injectors (Fig. 2) and fit according to the
instructions; when doing so, remember that there are
two different injector versions for each type of gas
(see Table 1).
Fig. 2
B Refit the main burner.
6 720 607 716
GAS PRESSURE CONVERSION KIT
1.2
Adjusting the maximum gas flow
rate
B Undo and remove the sealing plug A (Fig. 3) on the
burner, then connect the pressure gauge
B Switch on the appliance and set the control at the
top left to the maximum setting.
B Adjust the pressure by means of screw B (Fig. 3)
according to the table provided.
Fig. 3
Required gas supply pressure:
• butane/propane: 50 mbar
• Lock screw B again.
Leakage test:
B Turn on gas cock.
B Switch on appliance.
B Test appliance and gas connections.
LH8/WR8
Appliance
LH10/WR10
LH8/WR8
Burner
pressure
(mbar)
LH10/WR10
Table 1
Injector code
1
2
66
66
70
72
20.8
24.7
11