Franklin Electric Little Giant PE-2.5F-PW Serie Guia De Inicio Rapido
Franklin Electric Little Giant PE-2.5F-PW Serie Guia De Inicio Rapido

Franklin Electric Little Giant PE-2.5F-PW Serie Guia De Inicio Rapido

Publicidad

Franklin Electric Co., Inc.
P. O. Box 12010
Oklahoma City, OK 73157-2010
405.947.2511 • Fax: 405.947.8720
www.LittleGiantPump.com
CustomerService-WTS@fele.com
INTRODUCTION
EN
This instruction sheet provides you with the information required to safely own and
operate your Little Giant pump. Retain these instructions for future reference.
The Little Giant pump you have purchased is of the highest quality workmanship
and material, and has been engineered to give you long and reliable service.
Little Giant pumps are carefully tested, inspected, and packaged to ensure safe
delivery and operation. Please examine your pump carefully to ensure that no
damage occurred during shipment. If damage has occurred, please contact the
place of purchase. They will assist you in replacement or repair, if required.
READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO
INSTALL, OPERATE, OR SERVICE YOUR LITTLE GIANT PUMP. KNOW THE
PUMP'S APPLICATION, LIMITATIONS, AND POTENTIAL HAZARDS. PROTECT
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION.
FAILURE TO COMPLY WITH THESE INSTRUCTIONS COULD RESULT IN
PERSONAL INJURY AND/OR PROPERTY DAMAGE!
SAFETY GUIDELINES
Make certain that the unit is disconnected from the power source before
attempting to service or remove any component.
Do not use to pump flammable or explosive fluids such as gasoline, fuel oil,
kerosene, etc. Do not use in explosive atmospheres. Pump should only be used
with liquids compatible with pump component materials.
Do not handle pump with wet hands or when standing on a wet or damp surface
or in water.
This pump is supplied with a grounding conductor and/or grounding type
attachment plug. To reduce the risk of electric shock. be certain that it is connected
to a properly grounded grounding type receptacle.
In any installation where property damage and/or personal injury might result from
an inoperative or leaking pump due to power outages, discharge line blockage,
or any other reason, a backup system(s) and/or alarm should be used.
Support pump and piping when assembling and when installed. Failure to do so
may cause piping to break, pump to fall, motor bearing failures, etc.
ELECTRICAL CONNECTIONS
1. Check the pump label for proper voltage required. Do not connect to voltage
other than that shown.
2. If pump is supplied with a 3-prong electrical plug, the third prong is to ground
the pump to prevent possible electrical shock hazard. DO NOT REMOVE the
third prong from the plug. A separate branch circuit is recommended. Do not
use an extension cord. Do not cut plug from the cord. If the plug is cut or the
cord is shortened, then this action will void the warranty.
3. If the cord is equipped with stripped lead wires, such as on 230v models,
be sure that the lead wires are connected to a power source correctly. The
(green/yellow) wire is the ground. The (blue or white) and the (brown or
black) are live.
CONSULT INSTRUCTION SHEET ILLUSTRATIONS FOR PROPER ASSEMBLY
AND DISASSEMBLY OF YOUR LITTLE GIANT PUMP.
1. The PE-2.5F-PW model pumps must be operated with the volute intake
below the liquid level.
2. The pumps can be placed in any position.
3. The weight of the pumps must be supported adequately. DO NOT support
the pumps by the discharge connection alone. Pumps may be supported
by using the two mounting holes in the back of the pump. The holes are
PE-2.5F-PW SERIES
MODÈLES DE LA
SÉRIE PE-2.5F-PW
MODELOS DE LA
SERIE PE-2.5F-PW
OPERATION
designed for #8 self-tapping screws. Hole depth is .37 – DO NOT exceed the
hole depth.
4. Do not attempt to restrict the intake side of these pumps. Restricting the
intake may cause damage to the seal and may starve the pump. If you
require reduced flow rates, then place a valve on the discharge side of the
pump or if flexible vinyl tubing is used, a clamp can be used on the tubing
to restrict the flow.
5. Do not let the unit operate dry. It is designed to be cooled by pumping fluid.
You may damage the seal and the motor may fail if the pump is allowed to
run dry.
6. If the unit is going to be idle for a period of time, follow the cleaning
instructions outlined in the next section. Do not let the unit freeze in the
wintertime. This may cause cracking or distortion that may destroy the unit.
7. If fused type plug is used on 230 volt units, a 2.0 amp fuse is
recommended.
SERVICE INSTRUCTIONS
MAKE CERTAIN THAT THE UNIT IS DISCONNECTED FROM THE POWER
SOURCE
BEFORE
ATTEMPTING
COMPONENT!
1. This unit is permanently lubricated. Oiling is not required. The power cord on
these units cannot be replaced. In case of damage the whole unit must be
replaced.
2. First remove the intake screen from the pump. Screen is snapped on and
can be removed by pulling. Then remove the three screws which attach the
volute.
3. Lightly clean any corrosion or debris which may clog the impeller. Use a
brush and penetrating oil and lightly scrape to remove encrusted material.
4. Turn the impeller by hand to make sure it turns freely. Set pump down so
the pump and impeller are not touching anything. Plug the unit into GFCI
circuit for 10 seconds to see if the impeller turns: a) If it is rotating and GFCI
did not trip, unplug unit and install parts in reverse order in which they were
removed. b) If it does not rotate, if pump is tripping circuit breakers, or not
operating properly after cleaning, return to Little Giant or its authorized
service center. DO NOT attempt repairs yourself.
5. Be certain power cord is in good condition and contains no nicks or cuts.
INTRODUCTION
FR
Cette feuille d'instructions vous fournit les informations nécessaires pour entretenir
et faire fonctionner votre produit Little Giant. Conserver ces directives afin de
pouvoir les consulter plus tard.
Le produit Little Giant que vous avez acheté a été soigneusement fabriqué avec
des matériaux de la plus haute qualité et a été conçu pour durer longtemps
et offrir un service fiable. Les produits Little Giant sont soigneusement testés,
inspectés et emballés afin d'en assurer la sécurité de fonctionnement et une
livraison en bonne condition. Vérifier attentivement le produit afin de vous
assurer qu'il n'a pas été endommagé pendant le transport. S'il est endommagé,
veuillez contacter l'entreprise qui vous l'a vendu. Si une réparation ou un
remplacement est requis, elle vous prêtera assistance.
LIRE ATTENTIVEMENT CES DIRECTIVES AVANT DE PROCÉDER À
L'INSTALLATION, À L'UTILISATION OU À L'ENTRETIEN DU PRODUIT LITTLE
GIANT. SE FAMILIARISER AVEC LES APPLICATIONS, LES LIMITES ET LES
RISQUES POTENTIELS DU PRODUIT. ASSURER SA PROPRE PROTECTION
ET CELLE DES AUTRES EN SUIVANT TOUTES LES RÈGLES DE SÉCURITÉ.
LE NON-RESPECT DE CES DIRECTIVES PEUT ENTRAÎNER DES BLESSURES
ET/OU DES DOMMAGES MATÉRIELS!
DIRECTIVES DE SECURITE
Veiller à débrancher l'appareil de sa source d'alimentation électrique avant
l'entretien ou la dépose d'une ou de plusieurs piéces.
Ne pas pomper des fluides explosifs ou inflammables tels qu'essence, mazout,
kérosène, etc. Ne pas employer dans une atmosphère comportant des risques de
déflagration. La pompe ne doit servir qu'à pomper des liquides compatibles avec les
matériaux utilisés pour la fabrication des éléments qui la composent.
Ne pas manipuler la pompe les mains humides, les pieds posés sur une surface
mouillée ou humide, ou les pieds dans l'eau.
Cette pompe est équipée d'un conducteur de mise à la terre et ou d'une fiche de
branchement à prise de terre. Pour réduire les risques d'électrocution, s'assurer
TO
SERVICE
OR
REMOVE
ANY
1

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Franklin Electric Little Giant PE-2.5F-PW Serie

  • Página 1 4. Do not attempt to restrict the intake side of these pumps. Restricting the SÉRIE PE-2.5F-PW intake may cause damage to the seal and may starve the pump. If you Franklin Electric Co., Inc. require reduced flow rates, then place a valve on the discharge side of the P. O. Box 12010...
  • Página 2: Introducción

    qu’elle est bien raccordée à une prise de courant appropriée comportant une 4. Faire tourner la roue à la main pour s’assurer qu’elle tourne librement. borne de mise à la terre. Placer la pompe de telle manière que la pompe et la roue à l’écart de tout ebjet.
  • Página 3: Funcionamiento

    CONSULTE LAS ILUSTRACIONES DE LA HOJA DE INSTRU-CCIONES, PARA 2. En primer lugar, quite la rejilla de la toma de la bomba. La rejilla se coloca MONTAR Y DESMONTAR CORRECTAMENTE SU BOMBA LITTLE GIANT. a presión y puede quitarse tirando de ella. Luego, quite los 3 tornillos que sujetan el difusor.
  • Página 4: Garantia Limitada

    UNIDOS CONTINENTALES: Por favor, devolver la unidad defectuosa, con el porte ©2008 Franklin Electric Co., Inc. pagado, a la fábrica en 301 North MacArthur Blvd., Oklahoma City, OK 73127- Little Giant® is a registered trademark of Franklin Electric Co., Inc.

Este manual también es adecuado para:

Xfra254

Tabla de contenido