Self Regulating Pipe Heating System
INSTRUCTION SHEET
THIS PRODUCT HAS BEEN DESIGNED FOR USE ONLY AS
WATER PIPE NO-FREEZE PROTECTION. DAMAGE TO, OR
IMPROPER INSTALLATION, USE AND/OR MAINTENANCE OF ELECTRI-
CAL HEATING CABLE CAN RESULT IN FIRE, ELECTRICAL SHOCK AND/
OR FREEZING OF PIPE.
a
THIS IS A SAFETY ALERT SYMBOL. WHENEVER YOU SEE
IT ALWAYS CAREFULLY READ AND UNDERSTAND THE
WARNINGS THAT FOLLOW. BE ALERT TO THE POSSIBILITY
OF SERIOUS INJURY OR DEATH.
WARNING
a
ONLY use this product on water supply and drain pipes.
ALWAYS read AND comply with the following important
safety instructions. Failure to comply can result in serious
injury or death from fire or electrical shock.
F o r
m o r e
i n f o r m a t i o n , o r
nearest FreezedFree system supplier, call Monday-Friday, 9
EST 800/537-4732 (US), or 800/794-3766 (Canada).
These instructions MUST be
• Saved for future reference
• Made available to USER of heating cables
• Passed on to future owners
RECORD OF PURCHASE
Date purchased
__________________________________
Purchased from
__________________________________
Installed by________________________________________
Date installed _____________________________________
IMPORTANT SAFETY INSTRUCTIONS
• Heating cables MUST be installed in compliance with ALL Na-
tional, State and Local codes. Check with your local electrical
inspector for specific details.
• A LW AY S e x e r c i s e p r o p e r c a r e a n d c a u t i o n d u r i n g
i n s t a l l a t i o n a n d u s e o f t h e FreezedFree P i p e H e a t -
i n g S y s t e m . C A R E F U L LY f o l l o w a n d u n d e r s t a n d t h e
instructions and warnings provided for your safety.
• T h e
F r e e z e d F r e e
n e c t o r
h o u s i n g
a n d
i n s u l a t i o n w i t h v a p o r s e a l m u s t b e k e p t d r y a n d
waterproof to avoid possible electrical shock or fire.
• ONLY use the FreezedFree System on metal and plastic domestic
water pipes (such as PVC, PEX or polybutylene). NEVER use
product on flexible vinyl tubing (garden hose), on buried pipes,
on pipes carrying any fluid other than water, or ANY non-pipe
heating applications such as roof and gutter de-icing or driveway
snow melting.
• NEVER expose FreezedFree Cable to temperatures ABOVE 150°F
(66°C), this will shorten the life of the cable. BEFORE installing on
hot water pipes, ALWAYS set the water heater thermostat BELOW
150°F (66°C) (low to medium on most thermostats).
• ONLY use the Fused Plug Kit (10802 or 10803) for
making connections.
• NEVER alter the plug in ANY way.
• To avoid short circuits, NEVER twist the wires inside the Freez-
edFree Cable together OR allow them to touch each other or
the outer braid.
• ALWAYS remove old heating tapes or insulation.
• ALWAYS keep cable ends clean and dry.
• Seal the cable ONLY with the end seal provided.
• ONLY cut the FreezedFree Cable jacket at the ends
when attaching the fused plug and end seal.
• NEVER cut, nick, or allow the plastic jacket of the FreezedFree Cable
to be worn down. The braid MUST remain intact.
• NEVER install the cable where it might be hit or cut by something.
• NEVER install the cable where it might be damaged by rubbing
against rough surfaces.
• BEFORE installing the FreezedFree Cable, file and remove from the
pipe ALL sharp edges which might damage the cable. The cable
MUST touch ONLY smooth non-abrasive pipe surfaces.
• A L W A Y S p r o t e c t t h e C O M P L E T E s y s t e m f r o m
damage by animals or impact.
t h e
n a m e
o f
y o u r
-5
am
pm
o r a n g e
c a b l e
c o n -
f i b e r g l a s s
t h e r m a l
BEFORE YOU BEGIN
Make sure you have selected the CORRECT length heating cable for the pipe
to be protected (see Chart #1 or #2).
Your Fused Plug Kit (10802 or 10803) should contain:
• one fused plug body with a built-in, non-replaceable fuse
• one push on end seal
• "CAUTION" labels
• cable ties – 2 pcs.
ADDITIONAL TOOLS AND MATERIALS REQUIRED
• Application tape (Cat.No. HCA) or high quality electrician's
tape such as Scotch 44 or 33.
• 1/2" fiberglass pipe insulation with vapor seal.
• Wire cutters or heavy scissors
• Phillips #2 and slotted screwdrivers.
• Ruler or measuring tape.
HOW TO DETERMINE THE LENGTH OF CABLE
YOU NEED
(MAXIMUM CIRCUIT LENGTH:75 FEET)
STEP 1 COLLECT THE FOLLOWING
NECESSARY INFORMATION
• Pipe size
• outside diameter
• length
• Lowest expected air temperature
(disregard windchill: it has been
figured into theLength Selection chart)
• Number of valves and spigots
• Distance from pipe to electrical outlet
• NEVER use nails, metal clamps, wires or other devices that might cut
the cable to support the cable along the pipe.
• Only use ½" or 1" vinyl or fiberglass tape to attach cable to pipe.
• Inspect the FreezedFree Cable for damage EACH TIME you plug it in.
If left plugged in all year, inspect it AT LEAST once a year or ANY time
you have reason to suspect damage.
• I f y o u s e e a c u t , n i c k o r w o r n s p o t o n t h e c a b l e ,
IMMEDIATELY disconnect the system and replace it.
• There are NO serviceable parts in the FreezedFree Cable System.
• NEVER splice a damaged cable.
• NEVER repair a damaged cable.
• ALWAYS replace a damaged cable with a new one.
• ALWAYS replace ANY damaged insulation and water-proof covering
after EACH inspection of the cable.
• O N LY c o n n e c t t h e p l u g t o a r e c e p t a c l e i n s t a l l e d
according to the National Electrical Code (or CEC) AND protected from
rain and other water.
• N E V E R i n s t a l l o r u s e F r e e z e d F r e e C a b l e w h e r e
flammable materials, liquids or vapors may be present. If the
cable is cut while the system is connected, the risk of fire is
increased.
• A LWAY S u s e a g r o u n d f a u l t p r o t e c t i o n d e v i c e ( G F P D )
t o r e d u c e t h e d a n g e r o f f i r e f r o m a d a m a g e d o r i m -
p r o p e r l y i n s t a l l e d h e a t i n g c a b l e . E l e c t r i c a l f a u l t
c u r r e n t s
c a u s e d
b y
erly installed cable MAY NOT BE LARGE ENOUGH to trip a
conventional circuit breaker.
• I f y o u D O N O T k n o w w h e t h e r y o u r e l e c t r i c a l s y s t e m
is protected by a GFPD, ALWAYS consult an electrician.
N O T E M a n y m o b i l e h o m e h e a t t a p e r e c e p t a c l e s a r e
NOT protected by a GFPD. A cord connected GFPD suitable
f o r o u t d o o r a p p l i c a t i o n s i s a v a i l a b l e f r o m E a s y H e a t
(cat.no. HCP1).
• In mobile home applications, ONLY connect the plug to an electrical
outlet UNDERNEATH the mobile home. The outlet MUST be in an un-
exposed, dry location because the plug is NOT weatherproof. NEVER
use an extension cord.
• To help prevent damage to the cable and the possibility of fire or electrical
shock, place the "Caution" label provided in the FreezedFree Plug Kit
(10802 & 10803) on the completed system where it can be EASILY
seen. This "Caution" label is REQUIRED by the National Electrical Code.
• Do not install heating cable when temperature is below -20°F (-29°C)
Examples
• 1 ½" PIPE
• 12 feet
• -20°F/-29°C
• 1 ball valve
• 2 feet
d a m a g e d
o r
i m p r o p -

Publicidad

loading

Resumen de contenidos para EasyHeat Freeze Free

  • Página 1 BEFORE YOU BEGIN Make sure you have selected the CORRECT length heating cable for the pipe to be protected (see Chart #1 or #2). Self Regulating Pipe Heating System Your Fused Plug Kit (10802 or 10803) should contain: INSTRUCTION SHEET •...
  • Página 2 STEP 2 REFER TO THE LENGTH SELECTION CHARTS STEP 4 HOW TO ASSEMBLE AND INSTALL THE CABLE AND FUSED PLUG KIT These charts will tell you the length of the cable you need per foot INSTALLING THE END SEAL of pipe and also the recommended distance to leave between each spiral wrap of cable on the pipe.
  • Página 3 STEP 7 INSTALLING THE INSULATION Make sure that the ground braid covering the cable is in contact with the ground strip when the plug is reassembled. Thermal insulation protects the FreezedFree Cable and helps prevent Contact between the ground braid and ground strip com- pipe freezing.
  • Página 4 • The National Electrical Code requires that a heating cable system electrical outlet located on the underside of a mobile home MUST be WITHIN 2 feet of the cold water inlet. • ONLY connect the FreezedFree System to an electrical outlet so located. www.easyheat.com 14047-001 Rev. 12 ©2011 Easy Heat...
  • Página 5: Comprobante De Compra

    ANTES DE COMENZAR Asegúrese de que el largo del cable calentador sea ADECUADO para la tubería que va a proteger (vea el cuadro N. 1 o N. Sistema de calefacción para tuberías con regulación automática Su kit de enchufe fusibleado (10802 ó10803) debe contener: •...
  • Página 6 PASO 2 REMITASE A LOS CUADROS DE SELECCION DE LONGITUDES PASO 4 COMO ENSEMBLAR E INSTALAR EL CABLE Y EL JUEGO DE ENCHUFE CON FUSIBLE En estos cuadros, encontrará el largo de cable que necesitará por cada pie de tubería y también la distancia que deberá dejar entre cada vuelta de cable INSTALACION DEL SELLADOR DE EXTREMOS de la tubería.
  • Página 7 PASO 7 INSTALACION DEL AISLANTE Asegúrese de que el trenzado con conexión a tierra que cubre el cable esté en contacto con la tira con conexión a tierra cuando vuelva a ensamblar El aislante térmico protege el cable FreezedFree y evita que la tubería se el enchufe.
  • Página 8 DEBEN estar DENTRO de los 2 pies de distancia de la entrada de agua fría. • Conecte el sistema FreezeFree UNICAMENTE a un tomacorriente que cumpla con este requisito. www.easyheat.com 14047-001 Rev. 12 ©2011 Easy Heat...

Este manual también es adecuado para:

1081510805