Replacing the collection bag

Replace a defective collection bag. Em-
ploy only original collection bags (see
"Spare Parts"), otherwise the guarantee
claim is invalid.

Safekeeping

Keep the foliage vacuum in a dry, frost-
free location, which is inaccessible to
children.
Do not store the device in direct sun-
light; store it in dark or in reduced light
conditions.
Do not cover the device with nylon
bags, since moisture can form.
Clean the device thoroughly at the
season end and for storage during
wintering. Clean the collection bag by
removing it, emptying it and washing
with warm water and neutral soap. Re-
attach the dried bag again.
Ensure that all nuts, bolts and screws
are tightened so the equipment is in
safe, functional condition.

Technical Data

Electric leaf vacuum
Rated input voltage....... 230-240 V~, 50 Hz
Idling speed .................. 6000-15000 min
Input power ................................... 2600 W
Safety class ........................................
Air capacity .......................max. 14 m
Air speed .................... max. 140-270 km/h
Shredding rate ................................... 10:1
Content of the collection bag ...............40 l
Weight .......................................ca. 3.2 kg
Sound pressure level
(L
) ....................... 86 dB(A); K
pA
Sound power level (L
measured ............. 96.0 dB(A); K
guaranteed ............................. 99 dB(A)
Vibration (a
) .............. 4.5 m/s
h
.........ELS 2614-2 E
/min
3
= 3 dB
pA
)
WA
=3 dB
WA
; K=1.5 m/s
2
Noise and Vibration: Noise and vibration
values were determined according to the
standards and stipulations designated in
the Declaration of Conformity. The oper-
ating conditions during measuring and
the procedures used for measuring in
accordance with EN 15503, Appendix A,
Appendix B.
• Warning! During operation, this elec-
tric tool generates an electromagnetic
field which, under certain circum-
stances, may impair the functionality of
active or passive medical implants. To
reduce the risk of serious or lethal inju-
ries, we recommend that persons with
medical implants consult their doctor
and the manufacturer of their medical
implant before operating the machine.
Technical and optical changes can be
carried out in the course of the further
development without announcement. All
measures, references and information
contained in this operating manual are
therefore without guarantee. Legal claims,
which are made on the basis of the oper-
ating manual, cannot be considered.
This device is designed for operation on
a power supply network with a system
impedance Zmax at the transfer point
-1
(domestic connection) of a maximum of
II
0.28 Ohms. The user must ensure that the
device is operated only on a power supply
network that fulfils this requirement. If nec-
essary, the local power supply company
can be asked for the system impedance.