Troubleshooting - Briggs & Stratton ELITE Serie Manual Del Propietário

Ocultar thumbs Ver también para ELITE Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Briggs & Stratton Generac Generator Discount Parts Call 606-678-9623 or 606-561-4983

TROUBLESHOOTING

Problem
No AC output is available, but
generator is running.
Generator runs good at no-load
but "bogs" down" when loads are
connected.
Generator will not start; or starts
and runs rough.
Generator shuts down during
operation.
Generator lacks power.
Portable Generator
Cause
1.
One of the circuit breakers is
open.
2.
Fault in generator.
3.
Poor connection or defective cord
set.
4.
Connected device is bad.
1.
Short circuit in a connected load.
2.
Generator is overloaded.
3.
Shorted generator circuit.
1.
Fuel Valve is in the "Off" position.
2.
Failed battery.
Out of gasoline.
Load is too high.
www.mymowerparts.com
Correction
1.
Reset circuit breaker.
2.
Contact Authorized service facility.
3.
Check and repair.
4.
Connect another device that is in
good condition.
1.
Disconnect shorted electrical load.
2.
See "Don't Overload Generator".
3.
Contact Authorized service facility.
1.
Turn fuel valve to the "On"
position.
2.
Replace battery.
Fill fuel tank.
See "Don't Overload Generator".
16

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

01653016540189201893

Tabla de contenido