TSREH Silicone Rubber Enclosure Heaters
CONNECTING HEATER TO AC POWER
The heater is designed to operate at a specific voltage: Refer to the lead wire label
or stamp located on the heater for rated voltage and wattage. Failure to operate the
heater at its rated voltage could cause damage to the heater, surface being heated, or
contents.
All electrical connections must be made by qualified personnel and in
accordance with all local codes and regulations. Two wires (same color) should be
connected to the power source directly, through a junction box, or to a connector that
is mated to a receptacle connected to the power source. BriskHeat
Rubber Enclosure Heaters are non-polarized, allowing either wire to be connected to
the neutral or hot.
Properly sized circuit breakers must be used. The end-user is responsible for
providing suitable electrical protection device. It is highly recommended that a ground
fault circuit breaker be used.
®
© BriskHeat
Corporation. All rights reserved
®
TSREH Silicone
.
5
TSREH Silicone Rubber Enclosure Heaters
EMERGENCY PROCEDURES
Read and understand these procedures prior to using this heater.
Disconnect power to the heater in the event of an emergency.
Electric Shock:
Do not touch the injured person while they are still in contact with the electrical current.
Call your local emergency service if the injured person experiences: severe burns,
confusion, difficulty breathing, heart rhythm problems, cardiac arrest, muscle pain and
contractions, seizures or a loss of consciousness.
Minor Burns:
Hold the burned area under cool running water for 10-15 minutes.
Remove rings or other tight items from burned area.
Major Burns:
Call your local emergency service.
Protect the person from further harm.
Remove rings or other tight items from burned area.
Monitor breathing and perform CPR if necessary.
Fire:
Call your local emergency service.
If it is safe to do so, use a fire extinguisher to fight the fire, otherwise evacuate to a safe
distance and wait for help to arrive.
This heater is built from material that will not support a flame but could ignite nearby
combustible material.
®
© BriskHeat
Corporation. All rights reserved
.
6