Firman 1815 Manual De Operaciones página 4

Kit de ensamblaje con manguera (25ft(7.62m)) de conexión rápida de 1/2" para gas natural (gn)
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Follow below instruction for leak test:
1.Connect the Quick Connect Adapter to Natural Gas (NG) Piping. Make sure there is a NG Shut
Off Valve present (Figures 3 and 4). Make sure the Quick Connect Hose Assembly is NOT
connected to the Adapter before proceeding.
NOTICE: The male outlet must be 1/2" NPT . If not ,additional fittings will be needed to complete
the installation. The additional fittings are not included.
Figure 3
The thread size and type of the fittings and connections shall be compatible with each other. Use
NG resistant pipe sealant(dope) on all NG threaded connections.
2. Turn on gas supply.
3. Check all the connections and joints with ammonia free soapy water solution or leak detection
solution. Bubbles that appear to grow in size are the indication of a gas leak (Figures 5 and 6).
Figure 5
4. If there is a leak, turn off the gas and then tighten fittings until bubbles do not appear at the joints.
Reapply gas resistant pipe sealant(dope) as needed.
Do not attempt to use the Hose until all gas leaks have been repaired.
English
Pipe Nipple
Quick Connect Adapter
Figure 4
03
NG Shut Off Valve
NG Piping
Figure 6
Customer Service: 1-844-FIRMAN1