Controls And Indicators; Inspections Prior To Starting; Starting And Stopping; Vacuum Cleaner Operation - American Sanders CAV 50 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Controls and indicators

Figure 5
2.
Start/Stop indicator and button
If the indicator is lit, the motor is ON.
You can start/stop each motor with this button.
5.
Stop button
This button stops all the motors simultaneously when
pressed (but doesn't turn the power of the vacuum
cleaner off).
6.
Low compressor pressure alarm indicator (only used with
automatic fi lter cleaning option with air compressor)
If lit, this indicates low air pressure inside air tank
7.
Max. vacuumed level indicator (if installed)
If lit, this indicates the maximum level of the vacuumed
material has been reached in the container, if the
level control for liquids or solids has been installed on
machine.
8.
Power supply indicator
Indicates the vacuum cleaner is energized.
9.
Primary fi lter indicator
Green - Indicates the primary fi lter is functioning properly.
Red - Indicates the primary fi lter is blocked and needs to
be cleaned.
10.
HEPA fi lter indicator (if installed)
Red - Indicates the HEPA fi lter is blocked and should be
replaced.
11.
Manual fi lter shaker knob (models with manual fi lter
shaker)
Figure 6
1.
Dust Container release lever
2.
Castor lever
3.
Closing band lever
5.
Electric power cable
6.
Handle
7.
Depressor hose
Figure 7
1.
Inlet

Inspections prior to starting

Prior to starting, check that:
The fi lters are installed;
All the levers are locked in place;
The vacuum hose and tools have been correctly fi tted to
the inlet (1 - Fig. 7);
The bag is installed, if applicable.
WARNING!
Do not use the vacuum cleaner if the fi lter is faulty.
04/2010

Starting and stopping

Figure 8
WARNING!
Lock the castor brakes (1) before starting the vacuum
cleaner.
Install a poly-liner in the container. The poly-liner
provides quick convenient disposal.
Press button (
2) to start each vacuum motor
Press button (
2) again to stop each motor or press "stop"
button to stop all motors at once.

Vacuum cleaner operation

WARNING!
The air speed in the suction tube should not be less
than 20 m/s.
If the air speed drops below this rate, the red indicator
light will illuminate on the primary fi lter.
When using the vacuum cleaner, check:
The state of the max. vacuumed material level indicator
(7 - Fig. 5) if the level check is installed.
The state of the primary fi lter (
fi lter (if installed) (10 - Fig. 5).
The state of the low compressor pressure indicator (
Fig. 5) (if installed).
WARNING!
If one of the indicators is lit, follow the instructions.
Symbol
Indicator signal
Low compressor
pressure
(6 - Fig. 5)
bar/psi
MAX
Max. vacuumed
material level
(7 - Fig. 5)
Primary fi lter
(9 - Fig. 5)
HEPA fi lter
(10 - Fig. 5)
WARNING!
Consult the "Troubleshooting" chapter if faults occur.
7
CAV 50 - CAV 100
9 - Fig. 5) and the HEPA
6 -
Indicator
Vacuum cleaner state
color
and procedure
Suction stopped.
Check the compressor
Red
is functioning properly (if
installed).
Suction stopped.
Empty the container
Red
(See relevant
paragraph).
Suction on.
Use the primary fi lter
shaker after stopping
Red
the vacuum cleaner (on
models with a manual
fi lter shaker).
Suction on.
Change HEPA fi lter
Red
(See relevant
paragraph).
C346
US

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Cav 100

Tabla de contenido