INSTRUCTION SHEET FOR FEDERAL MODEL 141-120 Electraflash
I. INSTALLATION.
Failure to follow all safety precautions and instructions may result in property damage,
Follow all instructions shipped with this product. This device is to be installed by a trained
electrician who is thoroughly familiar with the National Electrical Code and will follow the NEC
Guidelines as well as local codes.
The selection of the mounting location for the device, its controls and the routing of the wiring is
to be accomplished under the direction of the facilities engineer and the safety engineer.
In addition, listed below are some other important safety instructions and precautions you
should follow:
• Read and understand all instructions before installing or operating this equipment.
• Do not connect this light to the system when power is on.
• After installation, test the light system to ensure that it is operating properly.
• After testing is complete, provide a copy of this instruction sheet to all operating personnel.
• Establish a procedure to routinely check the light system for proper activation and operation.
A. Unpacking.
After unpacking the Model 141, examine it for damage that may have occurred in transit.
If the equipment has been damaged, do not attempt to install or operate it. File a claim
immediately with the carrier stating the extent of the damage. Carefully check all envelopes,
shipping labels and tags before removing or destroying them.
B. Mounting.
The Model 141 can be mounted on a flat surface or a
This light is UL listed for indoor or outdoor use. If the light is used outdoors, it MUST be
mounted with the base down. The light has been investigated by UL as meeting Type 3R
(rainproof) enclosure requirements.
Mounting hardware and installation details are left to the installer.
C. Electrical Connections.
Connect the two black power leads to a 120Vac power source.
A green wire is provided for connection to earth ground, when required by building codes.
II. MAINTENANCE.
Failure to follow these safety precautions may result in property damage, serious injury,
The Federal factory will service your equipment or provide technical assistance with any
problems that cannot be handled locally.
Any units returned to Federal Signal for service, inspection, or repair must be accompanied by a
Return Material Authorization. This R.M.A. can be obtained from the local Distributor or
Manufacturer's Representative.
WARNING
serious injury, or death to you or others.
SAFETY MESSAGE TO INSTALLERS
WARNING
Do not connect wires when power is applied.
WARNING
or death to you or others.