RSS-GEN warnings
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science
and Economic Development Canada's licence-exempt RSS(s). Operation is subject to the following
two conditions:
1. This device may not cause interference.
2. This device must accept any interference, including interference that may cause undesired
operation of the device.
L'émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR
d'Innovation, Sciences et Développement économique Canada applicables aux appareils radio
exempts de licence. L'exploitation est autorisée aux deux conditions suivantes :
1. L'appareil ne doit pas produire de brouillage;
2. L'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible
d'en compromettre le fonctionnement.
Product specifications
Displayed temperature range:
93.2 – 108 °F
Operating ambient temperature range:
50 – 104 °F
Storage temperature range:
-13 – 131 °F
Operating and storage relative humidity:
10-95% RH (non condensing)
Display resolution:
0.1 °F or °C
Accuracy for displayed temperature range
Maximum Laboratory Error
35 – 42 °C (95 – 107.6 °F):
±0.4 °F
Outside this range:
±0.5 °F
Clinical repeatability:
±0.26 °F
Reference Body Site: Oral Equivalent
Battery life:
2 years / 350 measurements /100 minutes flashlight time
Service life:
5 years
This thermometer is specified to operate at 1 atmospheric pressure or at altitudes with an atmospheric
pressure up to 1 atmospheric pressure (700 - 1060 hPa).
40 °C
10 °C
Type BF Applied Part
Consult Instructions for Use
Operating temperature
Subject to change without notice.
This appliance conforms to the following standards:
This infrared thermometer meets requirements established in ASTM Standard (E 1965-98) as it pertains to
infrared thermometers. Full responsibility for the conformance of this product to the standard is assumed by
Kaz USA, Inc. The ASTM laboratory accuracy requirement in the display range of 98 to 102 °F (37 to 39 °C) for
IR thermometers is ±0.4 °F (±0.2 °C), whereas for mercury in- glass and electronic thermometers, the
requirement per ASTM Standards E 667-86 and E 1112-86 is ±0.2 °F (±0.1°C).
Standard Reference Edition Title:
ASTM E1965-98: Standard Specification for Infrared Thermometers for Intermittent Determination of Patient
Temperature.
ISO 80601-2-56: Medical electrical equipment - Part 2-56: Particular requirements for basic safety and
essential performance of clinical thermometers for body temperature measurement.
12
(34 – 42.2 °C)
(10 – 40 °C)
(-25 – 55 °C)
(±0.2 °C)
(±0.3 °C)
(±0.14 °C)
Attention, consult
Storage temperature
Keep dry
accompanying documents
IEC 60601-1: Medical electrical equipment – Part 1: General requirements for basic safety and essential
performance.
ISO 14971: Medical devices – Application of risk management to medical devices.
ISO 10993-1: Biological evaluation of medical devices – Part 1: Evaluation and testing within a risk
management process.
IEC 60601-1-2: Medical electrical equipment – Part 1-2: General requirements for basic safety and essential
performance – Collateral standard: Electromagnetic compatibility – Requirements and tests.
ISO 15223-1: Medical devices. Symbols to be used with medical device labels, labelling and information to
be supplied. General requirements.
IEC 60601-1-11: Medical electrical equipment – Part 1-11: General requirements for basic safety and essential
performance – Collateral standard: Requirements for medical electrical equipment and medical electrical
systems used in the home healthcare environment.
MEDICAL ELECTRICAL EQUIPMENT needs special precautions regarding EMC. For detailed description of
EMC requirements please contact your authorized local Service Center (See guarantee card).
Portable and mobile RF communications equipment can affect MEDICAL ELECTRICAL EQUIPMENT.
Please do not dispose of the product in the household waste at the end of its useful life.
To protect the environment, dispose of empty batteries at appropriate collection sites according to
national or local regulations.
Limited three year warranty
You should first read all Instructions before attempting to use this product.
A. This 3 year limited warranty applies to repair or replacement of product found to be defective in
material or workmanship. This warranty does not apply to damage resulting from commercial, abusive,
unreasonable use or supplemental damage. Defects that are the result of normal wear and tear will not
be considered manufacturing defects under this warranty. KAZ IS NOT LIABLE FOR INCIDENTAL OR
CONSEQUENTIAL DAMAGES OF ANY NATURE, ANY IMPLIED WARRANTY OF MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE
DURATION OF THIS WARRANTY. Some jurisdictions do not allow the exclusion or limitation of
incidental or consequential damages or limitations on how long an implied warranty lasts, so the above
limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you
also may have other rights which vary from jurisdiction to jurisdiction. This warranty applies only to the
original purchaser of this product from the original date of purchase.
B. At its option, Kaz will repair or replace this product if it is found to be defective in material or
workmanship.
C. This warranty does not cover damage resulting from any unauthorized attempts to repair or from any
use not in accordance with the instruction manual.
Call us toll-free at 1-800-477-0457 or e-mail: ConsumerRelations@HelenofTroy.com
Please be sure to specify a model number.
NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CONSUMER RELATIONS FIRST OR SEE
YOUR WARRANTY. DO NOT RETURN THE PRODUCT TO THE ORIGINAL PLACE OF PURCHASE. DO
NOT ATTEMPT TO OPEN THE THERMOMETER HOUSING YOURSELF, DOING SO MAY VOID YOUR
WARRANTY AND CAUSE DAMAGE TO THE PRODUCT OR PERSONAL INJURY.
13