min/max continuous measurement:
The LC display shows the max value, the min value, the differential
value and the current value.

Important notices

– The laser points to the location that will be measured.
No objects may get into the laser's line of measurement.
– The device compensates the measurement for different room
temperatures. Therefore allow the device a brief adaptation period
when changing locations with large temperature differences.
– The device is only conditionally useable in outdoor areas and cannot
be used in strong sunlight.
– The measurement results of outdoor measurements may be influenced
or falsified by rain, fog and snow.
– In unfavourable conditions, e.g. with poorly reflecting surfaces, the
maximum deviation may be greater than 3 mm.
– Carpeting, upholstery or curtains will not reflect the laser optimally.
Measure to flat surfaces.
– Measurements made through glass (window panes) can falsify
measurement results.
– An energy-saving function switches the device off automatically.
– Clean with a soft cloth. Water may not be allowed to penetrate the
housing.

Error codes:

Calculation error
Received signal too weak
Received signal too strong
Measuring time too long
Ambient light level too high
Temperature is too high: > 40°C
Temperature is too low: < 0°C
Hardware fault
12
EN
Press for 3 seconds
then release button
3 sec
1x
stop
2x