06. TROUBLESHOOTING
Malfunction
Ice maker does not work
Compressor starts and
stops after a brief run.
Ice making set is cooled
but the tank does not
have enough water.
Ice is not transparent.
Ice cubes are much
smaller then they
should be
28
Potential cause
Power supply button is in
the OFF position.
Improper power
connection.
No power supplied to the
socket outlet.
Ambient temperature too
high.
Low mains voltage.
Water tap is malfunctioning.
Low pressure in the water
supply system.
Tank drainage plastics leak
water.
Clogged water nozzle.
Dirty water tank.
Low pressure in the water
pump.
Turbid/dirty/hard water.
Insufficient quantity of
water.
Malfunctioning cooling
system.
Solution
Set the ON/OFF button to ON.
Ensure that the power
connections are verified by
competent experts.
Read the instructions for
selecting an ice machine
location.
The ice maker does not get
enough air.
Check the fuse for the
respective socket.
Read the instructions for
selecting an ice machine
location.
The ice maker does not get
enough air.
Clean the air filter.
Ensure that the power
connections are verified by
competent experts.
Contact the nearest Frozy
service center.
Check the pressure in the water
supply system, it must be above
1 bar.
Properly position the tank
discharge plastics in place.
Check the water nozzle for
spraying. Clean the nozzle if
clogged.
Clean the ice cube maker
following the cleaning
instructions.
Contact the nearest Frozy
service center.
Use water filter.
Properly position the tank
discharge plastics in place.
Check for leaks in the water
supply connection point.