Switches and other controls cannot be touched by a person in the bath or shower.
If in doubt, do not install. Herschel Infrared Ltd shall not be liable for any loss, damage or injury caused or
resulting from inadequate fitting or incorrect placement of heaters close to water sources.
POSITIONING:
This is an infrared panel heater designed specifically to fit in 60x60 cm ceiling grid tile spaces. It heats objects
by transferring energy directly from the heater into the object. The optimum position for the heater is
placement where it will not be obstructed by objects or where it cannot effectively radiate out, such as at
the edge or in the corners of a room. Objects placed in front of the heater will heat up and can prevent
effective heat dispersion into the room. Avoid placing it above windows or open doorways.
When ceiling mounting in a ceiling grid, to avoid overheating the unit,
materials onto the rear of the panel.
Objects in front of the panel must be at least 400mm away and 200mm away from the sides. The distance
from the sides of the heater must always be observed. Failure to do so will cause excess heat to build up
behind the heater and will void the warranty.
The distance between the sides of the heater and the sides of any adjacent heater must be at least one 60x
60 tile distance to avoid excess heat to build up between two heaters placed adjacent to each other. Failure
to observe this will void the warranty.
These heaters have no brackets and cannot be mounted on a ceiling surface. They can only be mounted in
a ceiling grid tile space. For ceiling mounting panels on a ceiling surface, please use the Herschel Select XLS
White panel range.
Select Ceiling Tile heaters are not intended for free-standing (portable) use.
If you are in any doubt, please check with your local dealer before mounting to the ceiling.
INSTALLATION:
WARNING:
Electrical installation should only be carried out by suitably qualified personnel.
Wiring to this appliance must be connected in accordance with the relevant national electrical safety
standards. It is a Class 1 appliance and must be earthed.
When placed in public areas, installation must comply with relevant local electrical standards. For certain
public buildings like schools and care homes the heaters must be installed according to the specific
legislation for these types of buildings.
The electrical supply to the unit should be provided by connecting to a circuit protected by a fuse or residual
current device (RCD) or Ground Fault circuit interrupter (GFCI ) suitable for the electrical rating of the
appliance. Temperature control must be effected by a Thermostat.
Colour coding used in the supplied mains cable: BROWN wire is to be connected to LIVE ('L'), the BLUE wire
to NEUTRAL ('N') and the GREEN/YELLOW wire to EARTH ('E').
CAUTION:
• Ensure mains power is OFF before commencing an installation involving fixed wiring.
ENGLISH
DO NOT
place any insulating