22. ATTENTION! Temporarily stop the operation of the UVC lamp, while treating the water or fish inside your pond with
additional care products.
3.2.
Pond Pump
Mains voltage and current type must agree with the information on the type plate.
Install the connection socket outlet in the water-protected area and at least 2 m away from the edge of the pond.
Always protect the mains plug from moisture.
Unplug the mains plug before performing any work on the pump, fountain or pond.
Do not operate the pump if there are people in the water (disconnect the pump from the mains supply beforehand!)
Important! If there is damage to the mains cables or the motor housing the complete pump is unusable and must
be disposed of. Repair is not possible because the connecting cable is permanently cast in the motor housing.
This pump is equipped with a permanent magnet, its magnetic fields can influence cardiac pacemakers, interfere
with electrical / electronic components and delete the data on data carriers.
People with cardiac pacemakers should always maintain a safety distance of at least 30 cm to the pump.
Attention! Use in garden ponds and the protected area of garden ponds is only permitted if the installation complies
with the valid regulations. Consult a qualified electrician. DO NOT use the pump in or on swimming pools!
4. Application areas
The MTS 6000 UV 7 is a compact and complete filtering system, specifically designed to clean garden lakes. Thanks to
its small size it is easy to position in a garden and to care for. This device will ensure crystal clean water to your pond.
This device has been developed for private use and not for industrial or commercial purposes.
5. Placing in service
When tightening threaded connections, please do not apply excessive force which may cause damage.
Please observe the illustrations, too, which are contained as an attachment at the end of the present operating
instructions. The numeric and other details included in brackets below refer to these illustrations.
5.1.
Mounting
The filter comes equipped with all the necessary accessories. To install, position the container in the most suitable spot,
being careful to direct the drain towards the pond.
WARNING: The filter must be placed in an elevated position with respect to the water level of the lake.
WARNING: The filter should be positioned horizontally so as to avoid abnormal spilling of the water.
Insert the 12 bioballs (11) into the three compartments of the container (12).
Open the air-tight bags and place the sponges (10) in the three compartments on the bioballs (sponges will gradually
return to their original size).
Connect the pump with the UVC lamp with the hose and the joints (6+15) provided.
Make sure the inflow sealing (8) is inserted. Screw the filter cap (16) to the inflow cover (19). After having mounted the
pre-filter, immerse the pump, being careful that the suction system is distanced from the bottom.
To start the filter, insert the plugs of both the pump and lamp.
WARNING: Temporarily suspend the use of the UVC lamp if treating either water or fish.
ATTENTION:
- The filter must be placed above the water level of the pond.
- The filter must be positioned in horizontal position (to avoid any spill over of the water).
- To ensure the outflow of the water, the outlet of the filter shall not get reduced. In case an outlet hose or outlet tube
shall be used, make sure it is installed on a low slope towards the pond.
5.2.
Setting up at the garden pond
Place the filter above the water level (filter outflow at least 15 cm above the water surface) and ensure that the filter is at
least 2 meters away from your pond. The container should be placed horizontally on a solid substrate (stone slab).
Ensure, that it cannot fall into the water and that the installation area of the filter cannot be flooded.
It is best to set up the filter where it is in the shade. If the interior of your filter should become very hot, then its capacity is
reduced.
Always use the shortest possible hose length and avoid kinking the hose
For biological reasons, the immersion depth of the pond pump should be approx. 40 cm for optimal function of the filter
system. Ensure that the pond pump is placed on a silt-free substrate (stone slab).
5.3.
Placing in service
Attention! Comply with the safety measures specified for the UVC emitter and the pump (see above)! (See the
provided operating instructions).
Install the connection socket outlet in the water-protected area and at least 2 m away from the edge of the pond!
12