INTRODUCTION
The meter is a handheld 31/2 digital multimeter for measuring DC and AC voltage, DC cur-
rent, Resistance, Diode, Transistor and Continuity Test with battery operated.
SAFETY INFORMATION
This multimeter has been designed according to IEC 61010 concerning electronic measur-
ing instruments with an overvoltage category (CAT.II 600V, CAT.III 600V) and pollution grade
2. Follow all safety and operating instructions to ensure that the meter is used safely and is
kept in good operating condition.
Warning
• Never exceed the protection limit values indicated in specifications for each range of
measurement.
• When the meter is linked to measurement circuit, do not touch unused terminals.
• Never use the meter to measure voltages that might exceed 600V above earth ground in
category II installations.
• When the value scale to be measured is unknown beforehand, set the range selector at
the highest position. Before rotating the range selector to change functions, disconnect
test leads from the circuit under test.
• When carrying out measurements on TV or switching power circuits always remember
that there may be high amplitude voltages pulses at test points, which can damage the
meter.
• Always is careful when working with voltages above 60V dc or 30V ac rms. Keep fingers
behind the probe barriers while measuring.
• Before attempting to insert transistors for testing, always be sure that test leads have been
disconnected from any measurement circuits.
• Components should not be connected to the hFE socket when making voltage
measurements with test leads.
• Never perform resistance measurements on live circuits.
MAINTENANCE
• Before opening the case, always disconnect test leads from all energized circuits.
• For continue protection against fire; replace fuse only with the specified voltage and
current ratings:
-F1:FF 250mA H 600V, 10KA
-F2:FF 10A H 600V, 10KA
Never use the meter unless the back cover is in place and fastened completely.
• Do not use abrasives or solvents on the meter. To clean it using a damp cloth and mild
detergent only.
BATTERY & FUSE REPLACEMENT
• If "
" appears on display, it indicates that the battery should be replaced.
• Fuse rarely need replacement and blow almost always as a result of operator's error.
• To replace battery fuse
-F1:FF 250mA H 600V, 10KA
-F2:FF 10A H 600V, 10KA
• Remove the 2 screws in the bottom of the case. Simply remove the old, and replace with
a new one.
• Be careful to observe battery polarity.
WARNING
Before attempting to open the case, always be sure that test leads have been discon-
nected from measurement circuits. Close case and tighten screws completely before
using the meter to avoid electrical shock hazard.
ACCESSORIES
• Operator's summary instruction manual
• Set of test leads
• 9 volt battery. NEDA 1604 6F22 006P type
• Holster
ENG
ENGLISH
instruction manual:
APAC: MGL GLOBAL SOLUTIONS LTD
info.apac@mgl-intl.com
Flat 4-1, 4/F, No. 35, Section 3 Minquan
East Road. Taipei, Taiwan.
Tel: +886 2-2508-0877
EMEA: MGL EUMAN S.L.
info.emea@mgl-intl.com
Parque Empresarial Argame, 33163
Morcín. Asturias, Spain.
Tel: +34 985-08-18-70
Digital multimeter
See the full
AMERICAS: MGL AMERICA, LLC.
info.na@mgl-intl.com
US East Coast: 2810 Coliseum Centre
Drive, Ste. 100. Charlotte, North Carolina,
MGL EUMAN, S.L.
28217 USA
Parque Empresarial de Argame,
Tel: +1 833 533-5899
C/Picu Castiellu, Parcelas i-1 a i-4
US West Coast: 760 Challenger Street.
E-33163 Argame, Morcín
Brea, California 92821 USA
Asturias, España, (Spain)
Tel: +1 310-728-6220
www.mgl-intl.com
ENG

Publicidad

loading