Nimh/Nicd Battery Program - Hobbytech MULTI 80 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

LiPo STORAGE
2.0A
11.1V(3S)
Li3S 2.0A
12.59V
STO 022:43 00682
DiSCHArging LiTHiUM BATTEry
LiPo DISCHARGE
1.0A
11.1V(3S)
Li3S 2.0A 12.59V
DSC 022:43 00682
VOLTAgE BALAnCing AnD MOniTOring DUring THE DiSCHArgE
The processor monitors the voltage of individual cells during "storage-mode" and "discharge" of Lithium
battery pack. It tries to normalize the voltages to be equal. For this feature, the individual plug of the
battery pack should be connected to the individual port of the charger.
If the voltage of any one or more cells varies abnormally during the procedure, it terminates the process
forcibly with the error message. If this happens, the battery pack contains the bad cell, or the bad
connection of the cable or plug. You can easily know which one cell is bad by pressing inC button at time
of showing the error message.
BATTERY VOL ERR
CELL LOW VOL
4.14
4.16
4.09
2.18
0.00
0.00

niMH/niCD BATTEry PrOgrAM

These programs are for charging or discharging NiMH (Nickel-Metal-Hydride) or NiCd (Nickel-Cadmium)
battery commonly used for R/C models applications. To alter the value at the display, press start/Enter
key to make it blink then change the value using inC or DEC key. The value will be stored by pressing start/
Enter key once.
NiMH 2.0A 7.42V
CHG 022:45 00890
All manuals and user guides at all-guides.com
You can set up the current and the voltage of the battery pack to be charged.
The current will be used for charge or discharge the battery to reach the
"storage" level of voltage.
The screen shows the present situation during charge process. To stop
charging press Batt type/stop key once.
The value of discharge current on the left side of screen may not exceed 1C for a
maximum safety and the final voltage on the right should not be under the voltage
level that is recommended by the battery manufacturer to avoid deep discharging.
To start to discharge press start/Enter key for more than 3 seconds.
This shows the present state of discharge. To stop discharging press Batt
type/stop key once.
The processor found that the voltage of one of the cell in the Lithium battery
pack is too low.
In this case, the 4th cell is bad. If there happens the connection-break of the
cable or plug, the voltage value may show zero.
To start the process, press start/Enter button for more than 3 seconds.