21.3. Test run with control unit 47-21-0
Push the door manually to the "centre" position and lock the door (using the
emergency release).
Press the pulse button on the motor control board and let the door run by means
of the drive. Check the end positions. You can regulate the end positions by
moving the permanent magnets.
In the first two test runs of the door, the running time and the power
requirement are automatically saved. The running time determines the soft start
of the door, the power requirement determines the ampere stop.
21.4. Test run with control unit 47-21-i
The motor control unit 47-21-i is used to perform the learning runs in the menu
and to correct the end positions with the + and - buttons. Please refer to the
installation instructions for motor control unit 47-21-i under item "Learning
runs".
2 2 2 2 . . N N o o t t e e s s o o n n e e m m e e r r g g e e n n c c y y u u n n l l o o c c k k i i n n g g
To be able to push the door by hand, you must emergency
unlock the operator. To do this, operate the release lever
upwards.
If the door has no mechanical end stops, it can be pushed out of the guide in
the emergency unlocked state.
SAFETY WARNINGS FOR HAZARD AVOIDANCE
Make sure that the door has a mechanical end stop before moving the
emergency unlocked door.
WARNING
The gate must have a mechanical end stop!
32