2 2 3 3 . . P P l l u u g g c c o o n n n n e e c c t t i i o o n n s s
The radio transmission system of the main closing edge and the photocell
receiver are connected to each other by a 6-pole plug system as standard.
The upper terminal box of the drive portal has a 6-pole Clutch. All safety
devices have a plug cable and a Clutch line. All units form a series connection.
A terminating plug is located at the end of the series connection.
If a fault is suspected in a unit, it can be easily removed from the series
connection by simply disconnecting it. The remaining components again form a
new series connection.
The safety contact edges are equipped with a 3-pole plug-in screw system.
The upper terminal box has a 3-pole plug cable and a 3-pole coupling cable.
All safety contact edges also have a 3-pole plug line and a 3-pole coupling line.
All safety contact edges form an electrical connection with the terminal box.
a ring.
If a fault is suspected in the safety contact strips, the 3-pole plug and the 3-pole
coupling of the terminal box can be connected directly to each other. The
safety contact strips are then without function.
These plug systems are used for rapid troubleshooting and simplified
replacement of safety components.
After troubleshooting / repair, the door may only be put back into operation
with all connected, functional and necessary safety devices.
NOTE
33