Troubleshooting - PYD Electrobombas SH Serie Manual De Instalación Y Mantenimiento

Ocultar thumbs Ver también para SH Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTRUCTIONS MANUAL AND MAINTENANCE
SERIE SH
TROUBLE SHOOTING
PROBLEMS
The voltage is not correct.
The pump does
Fuse or thermal protector makes
not run
the pump stop running.
Too much high head
The pump
Too low water level
does not pump
Bottom valve not in water
properly
No water
Leakage of inlet pipe
The foot-valve is blocked.
The impeller is corrosive.
The pump runs
The bottom valve is not in the
but
water.
no water
No priming water.
Leakage in suction pipe.
The foot-valve is blocked.
The flow redu-
The head is too high.
ces
The water level is too low.
obviously
The impeller is serious damage.
The motor is
Low voltage
over
or insufficient ventilation in pump
heating
room
The pump
Low voltage
stops soon
or insufficient ventilation in pump
after starting
room
www.proindecsa.com / proindecsa@proindecsa.com
POSSIBLE REASONS
Check the voltage on the name plate.
Check the fuse or thermal protector.
Check the suitable head.
Check the suction head.
Have the valve in the water.
Fill the pump with water.
Check the suction conditions.
Check the suction height and re-install the
pump.Replace the impeller.
Fill the suction section with water.
Fill the pump with water.
Check the suction conditions.
Clean or replace the foot-valve.
Check the installation height.
Check the suction head and re-install the
pump.
Replace the impeller.
Contact the electric power company to supply
stable voltage.
Have good ventilation.
Contact the electric power company to supply
stable voltage.
Have good ventilation.
7
SOLUTION