OPERATION – SOLDERING STATION ONLY
1.
Device must be placed on stable work table, soldering iron must be placed into the holder.
2.
Fix the appropriate soldering tip and connect the device to the power source.
3.
Turn on the device with the main switch placed at the back of the device, turn on the soldering iron with switch (6),
it will start to heat.
4.
Temperature setting: set the desired temperature using buttons (14) and (15). Working (heating) indicator (19) will
glow. When the soldering iron reaches the set temperature, indicator will flash quickly. When the temperature drops,
the indicator turns off.
5.
Soldering iron sleep time setting, „SLEEP" is blinking: simultaneously press buttons (14) and (15) for about 3 se-
conds, then using these buttons set the desired sleep time (16). When the soldering iron is on, and not used (placed
in the holder), then after a set time, soldering iron will enter into sleep mode – display will show "SLP". If the iron
will be picked up from the holder, the device will exit from the sleep mode and enter into working mode – iron will
warms up to a previously set temperature.
6.
Soldering fumes absorption: soldering iron is equipped with soldering fumes absorption pipe. Absorption can be
turned on with switch (7), smoke suction power can be controlled by the knob (1). It is recommended to carry
out regular inspection and replacement of the smoke absorber filter, which is located on the front panel under the
smoke absorber tube nut (8). The absorber is designed for solder fume extraction only and may not be uses for
other purposes.
7.
The device can optionally be equipped with vacuum suction pen (with air hose and suction tips) designed for dis-
placement of the SMD elements when soldering. In order to use this vacuum suction pen, air hose must be connec-
ted to the smoke absorber socket (8). Suction power can be adjusted by knob (1).
8.
After work, the soldering iron should be placed into the holder. Turn off the soldering station by switch (6).
9.
If the device is not used for a long time, it should be completely disconnected from the power source.
OPERATION – SMD REWORK STATION ONLY
1.
Device must be placed on stable work table, SMD rework gun must be placed into the holder.
2.
Fix the appropriate nozzle and connect the device to the power source.
3.
Turn on the device with the main switch placed at the back of the device, turn on the SMD rework gun with switch
(5), gun is ready to work.
4.
Temperature setting: set the desired temperature using buttons (11) and (12). Working (heating) indicator (10) will
glow. When the SMD rework gun reaches the set temperature, indicator will flash quickly. When the temperature
drops, the indicator turns off.
5.
Airflow volume adjustment: set the desired airflow volume with knob (1). The volume will be visible on the indicator
(2).
6.
Setting the automatic (AUTO) or manual (MANUAL) SMD rework gun working mode: switching between modes:
press buttons (11) and (12) simultaneously for about 3 seconds – „AUTO" or „MANUAL" flashes, set the desired
working mode by pressing buttons (11) and (12), device will enter into chosen mode after a few seconds. In manual
mode, SMD rework gun working continuously. In automatic mode, SMD rework gun turns off when placed into the
holder. Chosen "AUTO" or "MANUAL" mode will be shown on the display.
7.
Cold airflow setting: during normal work of the device, press the knob-button (1) to enter into cold airflow mode.
Display will show "COL" and device starts cooling the SMD rework gun.
8.
After work, the SMD rework gun should be placed into the holder. Turn off the SMD rework by switch (5).
9.
If the device is not used for a long time, it should be completely disconnected from the power source.
Press buttons (12) and (14) simultaneously for about 3 seconds, the ⁰C or ⁰F will be flashing on the display. Set the desired
CHANGING THE TEMPERATURE UNIT (CELSIUS / FAHRENHEIT):
unit using buttons (12) and (14). Chosen unit will be shown on the display.
MEMORY BUTTONS CH1, CH2, CH3.
Device is equipped with memory buttons for saving entered data CH1, CH2, CH3.
Each button can save any configuration of all working parameters of the device: soldering iron temperature, SMD reworks
gun temperature, working mode of the SMD rework gun (AUTO or MANUAL), airflow volume, soldering iron sleep time,
temperature unit. When all needed parameters are entered, press the button CH1 or CH2 or CH3 for approx. 3 seconds.
After this time, the parameters will be stored under the button which was pressed. Later, pressing this button will cause
immediately operation of the device with these stored parameters.