Introduction
Overview
The KPS-PA440 is a portable, hand-held professional meter that measures AC/DC
voltage, AC/DC current, resistance, capacitance, diodes, continuity, frequency, duty cycle,
temperature and non-contact voltage. This meter is easy to use with one hand, suitable for
professional users or amateurs, and ideal for school or home use.
Precautions:
Users must follow standard safety instructions while using the meter:
• Once the meter is out of the package, check for any damage to the meter before using.
• Double check the meter to make sure all the components are in good condition.
• Check the test leads before operation. Check the test leads for damage to the insulation
or wires before use.
• Use the original test leads included in the package for best performance and safety. If
necessary, use compatible leads with same specifications as the originals.
• Make sure to set the meter to the correct functions and measuring range before taking
measurement.
• Do not use the meter on a circuit where the measuring range is over the capable range
specified in the user's manual.
• Do not touch the tips of the test leads when performing measurement.
• If the measurement is above 60V DC or 30V AC, make sure to keep fingers behind the
barrier and finger guards.
• Do not use the meter on a circuit if the voltage is above 600V.
• In manual mode, if the value to be measured is unknown, start the meter in the maximum
range and then adjust accordingly.
• Remove the leads from the circuit first before switching between functions.
• Disconnect power and discharge all capacitors before measuring resistance, capacitance,
continuity or diodes.
• Do not measure capacitance before the capacitors are discharged.
• Do not operate the meter near explosive gas, vapor or dust.
• Stop using the meter if the meter or test leads appear damaged or do not function properly.
• Do not use the meter unless the battery case is securely fastened to the back of the meter.
• Do not expose the meter to direct sunlight, heat, or moisture.
Measurement Preparation
• Make sure that when measuring current, the current being measured does not exceed the
maximum rated current. This can cause overheating and damage the meter.
• When measuring in manual range and the value to be measured is unknown, start in the
highest range and adjust the range as needed.
• Make sure to turn the rotary switch to the proper position before connecting the leads to
a circuit.
• When connecting to a circuit, connect the black lead (COM jack) first before connecting
the red lead (INPUT jack). Remove the leads in the opposite order when finished.
Maintenance
General Maintenance
• To avoid possible electric shock or personal injury, repairs or servicing not covered in this
manual should be performed only by qualified personnel.
• Before opening the meter, remove test leads from all circuits to avoid damage to the meter
or personal injury.
• To avoid electrical shock, remove test leads from input jacks before cleaning.
• To avoid false readings that could lead to possible electric shock, replace the batteries as
soon as the low battery indicator "
" appears.
• Clean the instrument case with a damp cloth and mild detergent. Do not use abrasives
or chemical solvents.
• Keep in mind the internal capacitors may retain dangerous voltages even when the
instrument is turned off.
• Remove the batteries if the meter is not going to be used for an extended period of time.
Battery Replacement
WARNING:
Remove the test leads from the meter before removing the battery case to avoid
electrical shock and injury.
• Replace the batteries once the display shows "
• Remove test leads and unscrew the battery cover and remove the cover.
• Replace the used battery with a new one.
• Replace the battery cover and tighten the screw.
Note:
Double check the polarity of the battery before replacing.
Test Leads Replacement
WARNING:
Replace the test leads with identical or compatible leads. Lead specs: 1000V 10A.
Replace test leads if leads become damaged or worn.
WARNING:
Use meet EN 61010-031 standard, rated CAT III 600V, or better test leads.
WARNING:
To avoid electric shock,make sure the probes are disconnected from the measured
circuit before removingthe rear cover.Make sure the rear cover is tightly screwed
before using the instrument.
ENG
" to avoid false readings.
Digital clamp meter
ENGLISH
Out of the Box
Check the meter and accessories thoroughly before using the meter. Contact your local
distributor if the meter or any components are damaged or malfunction.
Accessories
• Test leads
1 pair
• Summary instruction manual
1 piece
• 9V battery
1 piece
• Type-K Thermocouple
1 piece
• Case
1 piece
See the full
instruction manual:
APAC: MGL GLOBAL SOLUTIONS LTD
info.apac@mgl-intl.com
Flat 4-1, 4/F, No. 35, Section 3 Minquan
East Road. Taipei, Taiwan.
Tel: +886 2-2508-0877
KPS SOLUCIONES EN ENERGÍA, S.L.
Parque Empresarial de Argame,
EMEA: MGL EUMAN S.L.
C/Picu Castiellu, Parcelas i-1 a i-3
info.emea@mgl-intl.com
E-33163 Argame, Morcín
Parque Empresarial Argame, 33163
Asturias, España, (Spain)
Morcín. Asturias, Spain.
Tel: +34 985-08-18-70
ENG
AMERICAS: MGL AMERICA, LLC.
info.na@mgl-intl.com
US East Coast: 2810 Coliseum Centre
Drive, Ste. 100. Charlotte, North Carolina,
28217 USA
Tel: +1 833 533-5899
US West Coast: 760 Challenger Street.
Brea, California 92821 USA
Tel: +1 310-728-6220
www.mgl-intl.com

Publicidad

loading

Este manual también es adecuado para:

Kpspa440cbint