SW230.T / SW230.T.120
Input wiring.
The control unit is supplied with non-jumpered normally closed safety inputs (STOP, SCL, SOP).
Add a jumper between the common (COM) and the input you do not intend to use. LEDs DL2 DL4 and DL5 must be on.
Connecting control push buttons and keyswitch.
The contacts are normally open. Input SEQ (LED DL1) controls the opening or complete closing of the gate. Input PED (LED DL3) controls the opening
or partial closing of the gate. LEDs DL1 or DL3 and LED DL7 light up when the keyswitch or push buttons connected in parallel are operated.
N.O.
N.C.
N.C.
N.O.
24
EN