ELITE 4500
7.5
TROUBLESHOOTING
Type of malfunction
What else?
Unit does not start
Unit does not suck in
Air bubbles do not exit
at the return hose
Air bubbles exit from
the return hose
Unit does not
Unit has sucked in air
generate pressure
Unit reached pressure,
but the pressure
collapses during
spraying.
Unit reached pressure,
but the pressure
collapses during
spraying.
Unit does not generate
the max. pressure
possible. Paint
nevertheless exits at
the return hose.
* Refer to the Service Manual, form no 2418920, available for download at www.titantool.com
Possible cause
Engine out of gas
Inlet valve clogged
Inlet/outlet valve soiled /
foreign bodies drawn in
/ worn
Pressure control valve
turned down completely
Unit is sucking in outside
air
Air in the oil circuit
Suction filter clogged
Paint cannot be worked
in this state. Due to its
properties the paint clogs
the valves (inlet valve)
and the delivery rate is
too low.
Clogged filter do not let
enough paint pass
Tip clogged
Relief valve defective
Measures for eliminating the malfunction
Fill engine with gas
Press the inlet valve button until the stop is
reached several times by hand
Remove the valves and clean then (-> refer to
Section 2.2/2.3 of the Service Manual*) / replace
worn parts
Turn the pressure control valve to the right until
the stop is reached
Check: Suction system tightened properly?
Cleaning connection (if available) at rigid suction
tube screwed tight and not leaking? Inlet valve
button leaky? -> Replace wiper and O-ring (->
refer to Section 2.1 of the Service Manual*)
Bleed the oil circuit in the unit by turning the
pressure control valve completely to the left
and let it run approx. 2 – 3 min. Then turn the
pressure control valve to the right and set the
spraying pressure (repeat process several times,
if necessary).
Check the suction filter. If necessary, clean/
replace
Dilute the paint
Check/clean the (high-pressure filter) gun filter
Clean the tip (-> refer to Section 5.2)
Please contact Titan Technical Service
SERVICING
21