Upon lower oil level, oil refilling is required.
Fig.22: PREHLS52 / 042001 ;
PREHLS52/5 / 042031
6.2.2- For PREHLS7T/V/042021
The hydraulic system is a closed system with oil tank, oil pump and control valve.
Check oil level regularly with dipstick.
Low oil levels can damage the oil pump.
Oil Level should measure approx. 1 ~ 2 cm below the upper surface of the oil tank.
The oil should be completely changed once a year.
- Make sure moving parts stops and the log splitter is unplugged.
- Make sure that no dirt or debris finds its way into the oil tank
- Collect used oil and responsibly recycle.
- Following an oil change, activate the log splitter a few times without actually splitting
6.2.3- Recommended oil
Following hydraulic oils or equivalent are recommend for the log splitter's hydraulic
transmission system:
SHELL Tellus 22
MOBIL DTE 11
ARAL Vitam GF 22
BP Energol HLP-HM 22
6.3- Sharpening the wedge
After using the log splitters for some time or when required, sharpen the wedge of the log splitter
using a fine-toothed file and smooth any burrs or crushed area along the cutting edge.
Fig.23 : PREHLS7T / 042011