If (B – D) ≤ X ≤ (B – C), it is qualified and the display has normal display
If X > (B – C), it is overweight and the display flickers.
Acquisition of target value 
Press
long until the display shows [TAR ET], and then press
If F2.6 = 0, press
, the instrument will take the weight on current scale as the new target value and quit the setting interface.
If F2.6 = 1, the display shows [000000], to request manual change of target value. After change, press
quit setting interface.
FUNCTION OF ACCUMULATION SCALE F2.1 = 4 
Operation method 
In normal weighing state, when the scale is in , add weight to the scale and press
progress bar, it indicates that the current display weight is included accumulated value, and then it returns to normal weighing state. If the
display shows [--no--] for a second, and returns to the normal weighing state, it indicates operation is invalid. Reason: 1. Between two
accumulation operations, the scale must have back-to- process, otherwise, accumulation is refused. 2. Accumulation operation is effective
only when display weight≥F2.2 is set. 3. The scale is in dynamic state.
Adjustment, clearing and printing of accumulated value
In normal weighing state, press
display shows current total accumulated value [A 9. 00] and flickers. To clear accumulated value, press [Pr 20. ], to make flicker weight
be 0. Press
to print accumulated data. Press
Attention: set whether to be over detailed data or accumulated data in F4.6.
FUNCTION OF COUNTING SCALE F2.1 = 5 
Instrument display 
[c 128], showing current quantity.
Sampling method  
1.
Check whether the scale is in , if not, press
2.
Place materials counted on the scale.
3. Press
long until the display shows [ AMPLE], and then press
counted just now, and press
display shows [000000], input sample weight. Press
4. In this function, press
FUNCTION OF ANIMAL SCALE F2.1 = 6 
Operation method 
In normal weighing state, place the animal on the weighing platform and its weight must be ≥threshold value set in F2.2. Press
instrument will collect data sampling. After sampling, the average value of sampling data will be locked, showing A X.XXX. Press
print; press
or
12
on operation panel for more than 2 seconds, the display will show [Zero] for a second, and then the
for confirmation. The instrument saves sampling data and quits the sampling interface. If F2.6 = 1, the
to display switch between quantity and weight.
to quit the interface.
to show current target value and flicker.
to quit the interface.
for setting.
. If F2.6 = 0, the display shows [PC 00]. Input the quantity
, the instrument saves setting data and quits sampling setting interface.
USER'S MANUAL
TRANSERENITE ARX
to save setting data and
on operation panel, if the display shows [Add--]
,