KEUCO IXMO Manual De Instrucciones De Uso página 9

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 11
Settings
To get to settings mode, the supply voltage must be interrupted for a minimum of 10 s. After that, restore supply volta-
ge. The LED initially blinks 1x and then lights for approx. 3 s. After that the settings can be changed within the following
3 min.
Mode
Automatic fl ushing
Reset to factory
settings
Adjust detection zone
Adjust run-on time
Important information, please make sure to read!
Activation
Cover the lower half of the sensor window
with your fi nger for 10 s until the fi rst
acknowledgement fl ush of water occurs, and
then remove fi nger from sensor window. If the
desired setting level is not achieved, please
repeat the procedure.
Cover the lower half of the sensor window
with your fi nger for 15 s until the fi rst
acknowledgement fl ush of water occurs, and
then remove fi nger from sensor window. If the
desired setting level is not achieved, please
repeat the procedure.
Cover the lower half of the sensor window with
your fi nger for 20-55 s. Take away your fi nger
after the third acknowledgement fl ush of water.
Cover the lower half of the sensor window
with your fi nger for 25 s. The fourth
acknowledgement fl ush of water indicates that
the mode is active. Remove your fi nger after
the desired run-on time is achieved.
Confi rmation
The set state is indicated by the blinking of
the LED:
Blinking 1x = 12 hour interval
Blinking 2x = 24 hour interval
Blinking 3x = inactive
The LED blinks 5x and confi rms the reset.
The set state is indicated by the blinking of
the LED:
Blinking 1x = Level 5 (~14 cm)
Blinking 2x = Level 6 (~16 cm)
Blinking 3x = Level 7 (~18 cm)
Blinking 4x = Level 8 (~20 cm)
The set time is indicated by the blinking of the
LED:
Blinking 1x = 1 s
:
Blinking 10x = 10 s
EN
9

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ixmo 59512 011100

Tabla de contenido