Cleaning and care

• Wipe off powder coated surfaces with soft, moist rag. Do not clean heater with
cleaners that are combustible or corrosive.
• Remove debris from the burner to keep it clean and safe for use.

Problems checklist

PROBLEM
Pilot will not light
Pilot will not stay on
Burner will not light
Warning: If the appliance is in case of any defaults or problems of assembly or use, please don't try to modify it by
yourself, contact your supplier or distributor to solve it.
15
PROBABLE CAUSE
Gas valve may be OFF
Tank fuel empty
Opening blocked
Air in supply system
Loose connections
Debris around pilot
Loose connections
Thermocouple bad
Gas leak in line
Lack of fuel pressure
Pressure is low
Opening blocked
Control not ON
Thermocouple bad
Pilot light assembly bent
Not in correct location
SOLUTION
Turn the gas valve ON
Refill LPG tank
Clean or replace opening
Purge air from lines
Check all fittings
Clean dirty area
Tighten connections
Replace thermocouple
Check connections
Tank near empty. Refill LPG tank.
Tank near empty. Refill LPG tank.
Remove and clean
Turn valve to ON
Replace thermocouple
Place pilot properly
Position properly and retry
Distributed by/ Distribuido por:
Mobiclinic S.L.
Polígono Industrial Fridex, 38-39
41500 - Alcalá de Guadaira (Sevilla), Spain
Imported by/Importado por: Grupo R. Queraltó S.A.
Polígono Industrial El Pino, Calle Pino Albar, 24,
41016, Sevilla (Spain)
Egypt