General Safety Instructions; Safety Devices; Connection Cable - AL-KO Garden + Hobby TOP 1402 KT Manual Del Usuario

Ocultar thumbs Ver también para Garden + Hobby TOP 1402 KT:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 25
Safety instructions
Read and then follow the safety instructions..
Keep the safety instructions for subsequent use
and for any other owners of the machine.
Follow the safety instructions and precautions on
the machine.
Several models are described in this operating
manual. Note model numbers!

General safety instructions

Children and young people under 16 years of
age as well as persons under the influence of
alcohol, drugs or medication must not use the
machine.
Local regulations may specify the minimum age
of the user.
Observe the accident prevention regulations.
Keep hands and feet away from rotating parts.
The concrete mixer may be operated with
original spare parts only.
The concrete mixer may be repaired by
authorised specialist companies only.
The concrete mixer must not be switched on if
either the concrete mixer or the connection cable
is damaged.
Do not leave the concrete mixer unsupervised.

Safety devices

Motor protection switch
If the concrete mixer is overloaded, the motor
protection switch switches the motor off. The
motor
protection
disconnected.
If the motor protection switch has switched off
the concrete mixer, proceed as follows:
1. Disconnect the concrete mixer from the
power supply.
2. Eliminate the cause of the overload.
3. Leave the concrete mixer to cool down for
2–3 minutes, reconnect the power and
switch on the concrete mixer.
switch
must
not

Connection cable

Use only a rubber-insulated connection cable of
HO7RN-F quality with a cable cross-section of
3 x 1.5 mm². The type designation must be
identified on the connection cable.
The maximum permitted cable length is 50 m.
Use only one connection cable of adequate
length. It is not permitted to connect several
cables to each other.
Plug and socket must be made of rubber.
Connection cable, plug and socket must be
splash-proof.
The connection cable, plug and coupling socket
may be
repaired
companies only. A defective connection cable
(e.g. insulation cracked, cut, crushed or kinked)
must not be used.
Keep plug and socket connections dry.
Danger!
!
Do not damage or sever the connection
cable
If the connection cable is damaged, proceed as
follows:
1. Disconnect the cable from the power supply.
Electrical requirements:
TOP 1402 KT
230 V/50 Hz alternating current
Minimum cross-section
connection cable = 1.5 mm²
Minimum fuse mains connection = 10 A
be
Concrete mixer
by authorised
specialist
GB 1

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

112332

Tabla de contenido