Mounting information
The length of the panic bar should be chosen to achie-
ve the largest possible effective grip length.
Depending on the type of door, different fixing acces-
sories from those supplied may be required to fix the
panic bar, e.g. wooden door. Depending on the type of
wood, threaded couplings with M 5 internal thread and
M5 cheese head screws or 4.5 x ... mm cross-recessed
wood screws are to be used.
Correct and safe functioning of the HEWI panic bar to
a large extent depends on proper installation. The panic
device should be installed by qualified personnel only.
The square spindle supplied is designed for HEWI
locking plates. If other makes are used the pin must be
secured against moving!
A HEWI locking plate is to be used for door leaves (see
Figure 9b of the mounting information).
The fitter must give the instructions to the user and the
instructions must be kept in a safe place for the life of
the panic device.
After installing, check the function of the panic bar wit-
hout caps, the latch must be drawn in far enough!
Possible error: Lock and tilt gear mechanism do not
match (see Figure 15 of the mounting information).
Adjust the handle clearance on both sides (Figure 14 of
the mounting information).
For use in accordance with DIN EN 1125, the HEWI
panic bar is solely approved together with the locks
certified according to DIN EN 1125 of the lock manu-
facturers named in the following (table on the right).
If you have any questions, please contact HEWI
Hardware Support, Tel. +49 5691 82-300
Panic bar for equipping exit doors according to DIN EN
1125 - approval only in combination with approved
locks.
Lock manufacturers
Certificate of conformity No. 0432 - BPR - 0017
Tested lock versions – please refer to the lock manu-
facturer's documents
ASSA ABLOY Sicherheitstechnik GmbH
Bildstockstraße 20
72458 Albstadt
Telefon: +49 7431 123-0
Telefax: +49 7431 123-240
www.effeff.de
Certificate of conformity No. 0432 - BPR - 0040
Tested lock versions – please refer to the lock manu-
facturer's documents
Beyer & Müller GmbH & Co. KG
Hauptstraße 277
42579 Heiligenhaus
Telefon: +49 2056 93 17-0
Telefax: +49 2056 93 17 44
www.beyer-und-mueller.de
Certificate of conformity No. 0432 - BPR - 0091
Tested lock versions – please refer to the lock manu-
facturer's documents
KFV Karl Fliether GmbH & Co. KG
Heidestraße 11
42549 Velbert
Telefon: +49 2051 278-0
Telefax: +49 2051 278-167
www.kfv.de
Certificate of conformity No. 0432 - BPR - 0020
Tested lock versions – please refer to the lock manu-
facturer's documents
Wilka Schließtechnik GmbH
Mettmanner Straße 56-64
42549 Velbert
Telefon: +49 2051 20 81-0
Telefax: +49 2051 20 81-151
www.wilka.de
Panic bar PS160XA/PS111XA
Important information
HEWI | 9