The thermostove goes
into "modulation"
as it reaches the
temperature set on
the thermostat of the
thermostove even at
low temperatures of
the water in the boiler
High variability of
domestic hot water
temperature
Exits little hot water
Never turn off the heater by removing electricity.
Let always complete the shutdown cycle, otherwise you may damage the
structure and have trouble lighting in the future.
106
1. Modify the parameter for the
maximum smoke temperature
modulation to edit
2. Dirty stove: the fumes are too
high temperature.
1. Water ow is too high
1. Insuf cient water pressure in
the network
2. Tap or mixer clogged with
limescale
3. Water group clogged
4. The heat exchanger does not
work
5. Air in: pump cavitation for the
presence of air, the water does
not rotate.
1. Contact your Authorized Assistance Center
2. Clean the tube bundle
1. Reduce the ow of water (4/6 liters per minute)
1. Check the setting of the pressure reducing valve
2. Install a water demineralizer
3. Check and clean the sanitary kit
4. Replace the plate heat exchanger
5. Bleed the brake system, remove air by venting
the radiators.